Alternative Parts
Overview
Features and Benefits
- Highly accurate; supports EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22, and IEC 62053-23
- Compatible with 3-phase, 3- or 4-wire (delta or wye), and other 3-phase services
- <0.1% error in active energy over a dynamic range of 1000:1 at 25°C
- <0.2% error in active energy over a dynamic range of 3000:1 at 25°C
- Supports current transformer and di/dt current sensors
- <0.1% error in voltage and current rms over a dynamic range of 1000:1 at 25°C
- Please see data sheet for additional features.
Product Details
The ADE7854 is a high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs. The ADE7854 incorporates second-order, sigma-delta (Σ-Δ) analog-to-digital converters (ADCs), a digital integrator, reference circuitry, and all the signal processing required to perform total active and apparent energy measurement and rms calculations. A fixed function digital signal processor (DSP) executes this signal processing.
The ADE7854 is suitable for measuring active and apparent energy in various 3-phase configurations, such as wye or delta services, with both three and four wires. The ADE7854 provides system calibration features for each phase, that is, rms offset correction, phase calibration, and gain calibration. The CF1, CF2, and CF3 logic outputs provide a wide choice of power information: total active power, total apparent power, or the sum of the current rms values.
The ADE7854 includes waveform sample registers that allow access to all ADC outputs. The device also incorporates power quality measurements, such as short duration low or high voltage detections, short duration high current variations, line voltage period measurement, and angles between phase voltages and currents. The SPI and I2C serial interfaces can be used to communicate with the ADE7854. A dedicated high speed interface, the high speed data capture (HSDC) port, can be used in conjunction with I2C to provide access to the ADC outputs and real-time power information. The ADE7854 has also two interrupt request pins, IRQ0 and IRQ1, to indicate that an enabled interrupt event has occurred.
The ADE7854 is available in a 40-lead LFCSP RoHS-compliant package.
APPLICATIONS
- Energy metering systems
Product Categories
Product Lifecycle
Not Recommended for New Designs
This designates products ADI does not recommend broadly for new designs.
Evaluation Kits (1)
Documentation
Application Notes (4)
User Guides (1)
Product Highlight (1)
Frequently Asked Questions (1)
Design Resources
ADI has always placed the highest emphasis on delivering products that meet the maximum levels of quality and reliability. We achieve this by incorporating quality and reliability checks in every scope of product and process design, and in the manufacturing process as well. "Zero defects" for shipped products is always our goal.
PCN-PDN Information
Sample & Buy
The USA list pricing shown is for BUDGETARY USE ONLY, shown in United States dollars (FOB USA per unit for the stated volume), and is subject to change. International prices may differ due to local duties, taxes, fees and exchange rates. For volume-specific price or delivery quotes, please contact your local Analog Devices, Inc. sales office or authorized distributor. Pricing displayed for Evaluation Boards and Kits is based on 1-piece pricing.
Sampling:
Selecting the Sample button above will redirect to the third-party ADI Sample Site. The part selected will carry over to your cart on this site once logged in. Please create a new account there if you have never used the site before. Contact SampleSupport@analog.com with any questions regarding this Sample Site.