Addressing Power Supply Systematic Failures—Part 3: Protecting Against Back EMFs

Figure 1

   

Key Takeaways

  • Discrete back-EMF mitigation techniques force trade-offs between efficiency, board area, and diagnostic capability. Engineers must weigh blocking diodes, dissipating circuits, bulk capacitors, and bidirectional supplies to balance protection against implementation cost.
  • Integrated protection ICs like the LTC7000 and LTC4368 combine reverse-current, overvoltage, and fault diagnostics in one architecture. This approach achieves blocking-diode functionality without forward-voltage losses, streamlining IEC 61508 compliance.

Abstract

Back electromotive force (back EMF) generated by motors and other inductive loads can create reverse-polarity voltages and reverse currents capable of disrupting safety-related power systems. If left unmanaged, these effects may compromise system robustness and contribute to systematic failures that affect the reliability of safety functions. This article examines practical mitigation techniques and compares their trade-offs in terms of protection capability, efficiency, and implementation complexity. It further illustrates how modern integrated protection solutions can strengthen compliance with functional safety standards while improving overall system resilience.

Introduction

With the rapid adoption of functional safety in industrial automation and robotics, electric motors are increasingly used not only for motion control but also as integral parts of safety functions such as emergency stop, protective stop, and normal stop, where defined behavior under fault conditions is critical to risk reduction. Different standards (for example, IEC 61508, IEC 62061, ISO 10218, etc.) exist to provide guidance and requirements when designing safety-related systems for such applications. In this context, motors and other inductive loads connected to safety-related systems are accompanied by the challenge of being able to reinject electromagnetic energy back into the system during normal operation or fault events. Employing appropriate protection circuits in power supplies against inductive effects, such as those caused by back electromotive forces (back EMFs), not only helps ensure that safety functions operate as required on demand but also improves robustness against systematic failures. For this reason, this article presents practical insights and examples of design solutions used to address back EMFs.

All About Back EMFs

Back EMF is a voltage generated by an inductive load—such as a motor, solenoid, or relay coil—that opposes a change in current flowing through it. In normal operation, as shown in Figure 1a, energy supplied by a power source is stored in the magnetic field of the inductive element. When the current is reduced or abruptly interrupted (for example, during shutdown, fault clearing, or an emergency stop), the collapsing magnetic field forces the stored energy to be released as a voltage of opposite polarity, appearing at the load terminals and driving current back toward the source as shown in Figure 1b.

Figure 1. Back EMF basic operation.

The physical origin of back EMF is governed by Faraday’s law of electromagnetic induction. An inductor resists changes in current, and the induced voltage is proportional to the inductance L and the rate of change of current di/dt, expressed as v = L × di/dt. When a power supply energizes an inductive load, a magnetic field builds up around the winding. If the supply is suddenly switched off, that magnetic field collapses rapidly and induces a voltage that drives current in the opposite direction, behaving electrically as if a battery of reverse polarity was momentarily connected across the load. In the absence of a controlled energy dissipation path, the flyback voltage can greatly exceed the original supply voltage and may reach hundreds or even thousands of volts depending on system inductance, current level, parasitic capacitances, and switch characteristics.

This back-EMF issue becomes a systematic capability1 concern since it can be considered a source of systematic failure. Addressing it improves compliance with functional safety standards requirements, such as the measures against voltage breakdown listed in IEC 61508-2 Annex A, Table A.15,2 as well as the robot design requirements defined in ISO 10218.

Typical Solutions to Mitigate the Effects of Back EMFs

Several discrete solutions already exist that can be used to mitigate the effects of back EMFs. Four of them are shown in Figure 2.

Figure 2. Back-EMF discrete solution examples.

Adding a Blocking Diode and Flyback Diode

  • A blocking diode is connected in series with the power supply output to prevent reverse current generated by the inductive load from flowing back into the power source. A flyback diode, connected across the inductive load, provides a controlled path for the load current when the power supply is disconnected.
  • During turn-off, the energy stored in the magnetic field of the inductive load circulates through the flyback diode, limiting the voltage excursion across the load and reducing stress on both the power supply and downstream circuitry.

Adding a Dissipating Circuit

  • Another common method is to dissipate the regenerated energy in a dump resistor, sometimes referred to as a braking resistor.
  • When the supply voltage rises above a predetermined threshold due to energy returned from the inductive load, a switching circuit redirects the excess energy into the resistor where it is converted into heat.

Connecting a Bulk Capacitor

  • A large capacitor can be placed across the output to absorb spikes.3
  • Bulk capacitance is often added across the DC bus to absorb transient regenerative energy and reduce voltage excursions. The required capacitance depends on the stored mechanical energy, allowable bus voltage rise, and system shutdown conditions.

Using a Bidirectional Power Supply

  • Power supplies specifically designed for motor-drive applications often include the ability to both source and sink current.
  • Unlike conventional power supplies that only deliver energy to the load, multi-quadrant supplies4 can safely absorb regenerative energy returned from motors during deceleration or shutdown events. The absorbed energy is either dissipated internally or transferred back to an upstream source, depending on the system architecture.

Such techniques can also be combined on top of another depending on the design requirements. Typical pros and cons for each discrete solution are shown in Table 1.

Table 1. Discrete Solution Examples: Advantages and Disadvantages
Solution Advantages Disadvantages
Adding a blocking diode and forward block diode
  • Simple
  • Low cost
  • Preferred for low-power applications
  • Inefficient due to blocking diode’s forward voltage drop
  • Flyback diodes slow down the decay of inductive current, which can increase stopping time in applications requiring rapid de-energization
  • Additional discrete components increase solution size
  • Protection capability is fixed
Adding a dissipating circuit
  • Faster energy dissipation compared to flyback diodes
  • Improved control of regenerated energy during the deceleration of motors
  • Reduced risk of power supply overvoltage
  • Dump resistors require additional switching circuitry and thermal management considerations
  • As system power levels increase, resistor sizing and cooling requirements can become significant design challenges
Connecting a bulk capacitor
  • Low implementation complexity
  • Minimal additional control circuitry
  • Improved immunity to short-duration transient events
  • Provides limited protection capacity
  • If the stored energy exceeds the capacitor’s absorption capability, output voltage can still rise to damaging levels
  • Large capacitors also increase system size, cost, and inrush current during startup
Using a bidirectional power supply
  • Direct handling of regenerative current
  • Improved system efficiency
  • Reduced need for external protection components
  • Better support for highly dynamic motor applications
  • Increased system cost and complexity compared to conventional industrial power supplies

Using Analog Devices’ Integrated Protection Solutions

Although traditional discrete approaches can effectively mitigate back-EMF effects, they often require compromises in efficiency, board area, response time, and diagnostic capability. Modern integrated protection solutions combine multiple protection mechanisms into a single architecture, addressing multiple fault conditions simultaneously while minimizing power dissipation during normal operation. Typical features include integrating reverse-current protection, reverse-polarity protection, fast load disconnection, overvoltage protection, overcurrent protection, and diagnostic and fault monitoring functions that can contribute to achieving functional safety requirements at the system level.

The LTC7000/LTC7000-1 are high-side N-channel MOSFET controllers that operate from input voltages up to 135V, allow fast turn-on and turn-off times, and enable several protection features. Figure 3a shows the LTC7000 demo board (DC2537A), which can be readily used for application evaluation. In a back-EMF event, the controller prevents energy stored in the inductive load from being driven back into the power source, thereby protecting both the supply and upstream circuitry as shown in Figure 3b. This approach achieves the functionality of a blocking diode while eliminating the associated forward voltage losses.

Figure 3. Using a high-side switch to address back EMFs.

Analog Devices’ protection solutions not only cover a lot of safety features but also facilitate integration into safety-related architectures. When combined with other mitigation measures, for example, enhanced electromagnetic immunity as discussed in Part 2 of this series, as well as diagnostic functions (for example, the MAX42500 and the MAX6459) to detect other failures, such solutions (for example, the LTC4368), as shown in Figure 4, can help support compliance with functional safety standards.

Figure 4. Designing for functional safety with the LT3020, LTM8051, MAX6459, MAX42500, and LTC4368.

Conclusion

As functional safety adoption continues to expand across industrial automation and robotics, addressing back-EMF effects remains essential to maintaining the integrity of safety-related power systems. Effective protection strategies not only prevent damaging voltage excursions and reverse-current conditions but also help mitigate systematic failure mechanisms that can impact safety-function performance. By combining appropriate back-EMF protection with broader diagnostic and fault-management measures, designers can build more robust systems that support the requirements of IEC 61508, IEC 62061, and ISO 10218.

References

1Bryan Borres. “Designing Power Supplies for Industrial Functional Safety—Part 2: Creating a Safe Power Design.” Analog Devices, Inc., June 2026.

2Bryan Borres and Noel Tenorio. “Designing Power Supplies for Industrial Functional Safety—Part 1: What IEC 61508 Tells Us.” Analog Devices, Inc., July 2025.

3MT-101 Tutorial: Decoupling Techniques. Analog Devices, Inc., 2009.

4Victor Khasiev. “Bipolar, Bidirectional DC-to-DC Supply Sources and Sinks Current from 5 V to 24 V Input. Analog Devices.” Analog Devices, Inc., April 2020.

关于作者

Bryan Angelo Borres
Bryan Angelo Borres于2022年10月加入ADI公司,担任MMP-East的产品应用工程师。他拥有马普阿大学电力电子研究生学位。Bryan在开关电源设计研发领域拥有超过四年的工作经验。
Anthony Serquiña