Addressing Power Supply Systematic Failures—Part 3: Protecting Against Back EMFs
Addressing Power Supply Systematic Failures—Part 3: Protecting Against Back EMFs
2026年11月19日
Key Takeaways
|
Abstract
Back electromotive force (back EMF) generated by motors and other inductive loads can create reverse-polarity voltages and reverse currents capable of disrupting safety-related power systems. If left unmanaged, these effects may compromise system robustness and contribute to systematic failures that affect the reliability of safety functions. This article examines practical mitigation techniques and compares their trade-offs in terms of protection capability, efficiency, and implementation complexity. It further illustrates how modern integrated protection solutions can strengthen compliance with functional safety standards while improving overall system resilience.
Introduction
With the rapid adoption of functional safety in industrial automation and robotics, electric motors are increasingly used not only for motion control but also as integral parts of safety functions such as emergency stop, protective stop, and normal stop, where defined behavior under fault conditions is critical to risk reduction. Different standards (for example, IEC 61508, IEC 62061, ISO 10218, etc.) exist to provide guidance and requirements when designing safety-related systems for such applications. In this context, motors and other inductive loads connected to safety-related systems are accompanied by the challenge of being able to reinject electromagnetic energy back into the system during normal operation or fault events. Employing appropriate protection circuits in power supplies against inductive effects, such as those caused by back electromotive forces (back EMFs), not only helps ensure that safety functions operate as required on demand but also improves robustness against systematic failures. For this reason, this article presents practical insights and examples of design solutions used to address back EMFs.
All About Back EMFs
Back EMF is a voltage generated by an inductive load—such as a motor, solenoid, or relay coil—that opposes a change in current flowing through it. In normal operation, as shown in Figure 1a, energy supplied by a power source is stored in the magnetic field of the inductive element. When the current is reduced or abruptly interrupted (for example, during shutdown, fault clearing, or an emergency stop), the collapsing magnetic field forces the stored energy to be released as a voltage of opposite polarity, appearing at the load terminals and driving current back toward the source as shown in Figure 1b.
The physical origin of back EMF is governed by Faraday’s law of electromagnetic induction. An inductor resists changes in current, and the induced voltage is proportional to the inductance L and the rate of change of current di/dt, expressed as v = L × di/dt. When a power supply energizes an inductive load, a magnetic field builds up around the winding. If the supply is suddenly switched off, that magnetic field collapses rapidly and induces a voltage that drives current in the opposite direction, behaving electrically as if a battery of reverse polarity was momentarily connected across the load. In the absence of a controlled energy dissipation path, the flyback voltage can greatly exceed the original supply voltage and may reach hundreds or even thousands of volts depending on system inductance, current level, parasitic capacitances, and switch characteristics.
This back-EMF issue becomes a systematic capability1 concern since it can be considered a source of systematic failure. Addressing it improves compliance with functional safety standards requirements, such as the measures against voltage breakdown listed in IEC 61508-2 Annex A, Table A.15,2 as well as the robot design requirements defined in ISO 10218.
Typical Solutions to Mitigate the Effects of Back EMFs
Several discrete solutions already exist that can be used to mitigate the effects of back EMFs. Four of them are shown in Figure 2.
Adding a Blocking Diode and Flyback Diode
- A blocking diode is connected in series with the power supply output to prevent reverse current generated by the inductive load from flowing back into the power source. A flyback diode, connected across the inductive load, provides a controlled path for the load current when the power supply is disconnected.
- During turn-off, the energy stored in the magnetic field of the inductive load circulates through the flyback diode, limiting the voltage excursion across the load and reducing stress on both the power supply and downstream circuitry.
Adding a Dissipating Circuit
- Another common method is to dissipate the regenerated energy in a dump resistor, sometimes referred to as a braking resistor.
- When the supply voltage rises above a predetermined threshold due to energy returned from the inductive load, a switching circuit redirects the excess energy into the resistor where it is converted into heat.
Connecting a Bulk Capacitor
- A large capacitor can be placed across the output to absorb spikes.3
- Bulk capacitance is often added across the DC bus to absorb transient regenerative energy and reduce voltage excursions. The required capacitance depends on the stored mechanical energy, allowable bus voltage rise, and system shutdown conditions.
Using a Bidirectional Power Supply
- Power supplies specifically designed for motor-drive applications often include the ability to both source and sink current.
- Unlike conventional power supplies that only deliver energy to the load, multi-quadrant supplies4 can safely absorb regenerative energy returned from motors during deceleration or shutdown events. The absorbed energy is either dissipated internally or transferred back to an upstream source, depending on the system architecture.
Such techniques can also be combined on top of another depending on the design requirements. Typical pros and cons for each discrete solution are shown in Table 1.
| Solution | Advantages | Disadvantages |
| Adding a blocking diode and forward block diode |
|
|
| Adding a dissipating circuit |
|
|
| Connecting a bulk capacitor |
|
|
| Using a bidirectional power supply |
|
|
Using Analog Devices’ Integrated Protection Solutions
Although traditional discrete approaches can effectively mitigate back-EMF effects, they often require compromises in efficiency, board area, response time, and diagnostic capability. Modern integrated protection solutions combine multiple protection mechanisms into a single architecture, addressing multiple fault conditions simultaneously while minimizing power dissipation during normal operation. Typical features include integrating reverse-current protection, reverse-polarity protection, fast load disconnection, overvoltage protection, overcurrent protection, and diagnostic and fault monitoring functions that can contribute to achieving functional safety requirements at the system level.
The LTC7000/LTC7000-1 are high-side N-channel MOSFET controllers that operate from input voltages up to 135V, allow fast turn-on and turn-off times, and enable several protection features. Figure 3a shows the LTC7000 demo board (DC2537A), which can be readily used for application evaluation. In a back-EMF event, the controller prevents energy stored in the inductive load from being driven back into the power source, thereby protecting both the supply and upstream circuitry as shown in Figure 3b. This approach achieves the functionality of a blocking diode while eliminating the associated forward voltage losses.
Analog Devices’ protection solutions not only cover a lot of safety features but also facilitate integration into safety-related architectures. When combined with other mitigation measures, for example, enhanced electromagnetic immunity as discussed in Part 2 of this series, as well as diagnostic functions (for example, the MAX42500 and the MAX6459) to detect other failures, such solutions (for example, the LTC4368), as shown in Figure 4, can help support compliance with functional safety standards.
Conclusion
As functional safety adoption continues to expand across industrial automation and robotics, addressing back-EMF effects remains essential to maintaining the integrity of safety-related power systems. Effective protection strategies not only prevent damaging voltage excursions and reverse-current conditions but also help mitigate systematic failure mechanisms that can impact safety-function performance. By combining appropriate back-EMF protection with broader diagnostic and fault-management measures, designers can build more robust systems that support the requirements of IEC 61508, IEC 62061, and ISO 10218.
References
1Bryan Borres. “Designing Power Supplies for Industrial Functional Safety—Part 2: Creating a Safe Power Design.” Analog Devices, Inc., June 2026.
2Bryan Borres and Noel Tenorio. “Designing Power Supplies for Industrial Functional Safety—Part 1: What IEC 61508 Tells Us.” Analog Devices, Inc., July 2025.
3MT-101 Tutorial: Decoupling Techniques. Analog Devices, Inc., 2009.
4Victor Khasiev. “Bipolar, Bidirectional DC-to-DC Supply Sources and Sinks Current from 5 V to 24 V Input. Analog Devices.” Analog Devices, Inc., April 2020.
著者について
Bryan Angelo Borresは、アナログ・デバイセズのシニア機能安全エンジニアです。産業用の機能安全が専門であり、TÜV認定の機能安全エンジニアでもあります。コンポーネント設計者やシステム・インテグレータがIEC 61508などの産業分野向け機能安全規格に準拠した電源製品を設計できるようサポートを提供。8年以上にわたり、効率が高く堅牢性に優れるパワー・エレクトロニクス・システムの設計に携わってきました。IEC TC65/SC65A
Anthony Serquiñaは、アナログ・デバイセズ(フィリピン)のプロダクト・アプリケーション・マネージャです。2018年11月に入社。複数の市場を対象とし、電源製品の開発に向けてアプリケーションを担当しています。パワー・マネージメントIC、AC/DCやDC/DCのフロント・エンド電力変換といったパワー・エレクトロニクスの分野において、15年以上にわたる業務経験を有しています。セントルイス大学(フィリピン バギオ市)で電子