AD522
ObsoleteHigh Accuracy Data Acquisition Instrumentation Amplifier
Part Details
- Low Drift: 2.0µV/° C (AD522B)
- Low Nonlinearity: 0.005% (G = 100)
- High CMRR: >110dB (G = 1000)
- Low Noise: 1.5µV p-p (0.1 to 100Hz)
- Low Initial VOS: 100µV (AD522B)
- Single-Resistor Gain Programmable: 1≤G≤1000
- Output Reference and Sense Terminals
- Data Guard for Improving ac CMR
- Internally Compensated
- No External Components except
- Gain Resistor
- Active Trimmed Offset, Gain, and CMR
The AD522 is a precision IC instrumentation amplifier designed for data acquisition applications requiring high accuracy under worst-case operating conditions. An outstanding combination of high linearity, high common mode rejection, low voltage drift, and low noise makes the AD522 suitable for use in many 12-bit data acquisition systems.
An instrumentation amplifier is usually employed as a bridge amplifier for resistance transducers (thermistors, strain gages, etc.) found in process control, instrumentation, data processing, and medical testing. The operating environment is frequently characterized by low signal-to-noise levels, fluctuating temperatures , unbalanced input impedances, and remote location which hinders recalibration.
Documentation
Data Sheet 1
Application Note 4
Technical Articles 4
Technical Book 1
This is the most up-to-date revision of the Data Sheet.
Hardware Ecosystem
Parts | Product Life Cycle | Description |
---|---|---|
AD8226 | PRODUCTION | Wide Supply Range, Rail-to-Rail Output Instrumentation Amplifier |
AD8229 | PRODUCTION | 1 nV/√Hz Low Noise 210°C Instrumentation Amplifier |
AD8236 | PRODUCTION | 40 µA Micropower Instrumentation Amplifier |
AD8232 | RECOMMENDED FOR NEW DESIGNS | Single-Lead, Heart Rate Monitor Front End |
Latest Discussions
No discussions on AD522 yet. Have something to say?
Start a Discussion on EngineerZone®