Reference Design Spotlight on Precision Data Acquisition (DAQ) Systems

Precision DAQ systems require resolutions ranging from 16- to 24-bits, with sampling rates from a few Hz to several MHz. Choosing the proper ADC is an important design consideration, as well as the supporting circuitry, including the voltage reference, input drive amplifier, instrumentation amplifier, multiplexer, and power supply. Circuits from the Lab reference designs featured in the table below enable quick integration and evaluation, while expanding your knowledge of precision DAQ and signal chain design. Download DAQ reference designs brochure to learn more. (pdf)

Precision DAQ

About Circuits from the Lab® Reference Designs

These signal chain designs are commonly used as standalone solutions, or to build more complex circuits and subsystems.

Built and tested for function and performance by ADI's applications experts, they offer:

  • Comprehensive documentation
  • Complete design and integration files
  • Factory-tested evaluation hardware

Access the complete library.

CFTL_logo_registered

View complete Reference Design Circuit Notes for FREE using the links in the table below

Reference
Design

Res (Bits)
Sample Rate
 # of Ch
Converter Architecture
Input Signal Range
Power Dissipation
Data Output Format

Additional Features

Pricing ($/ea)
CN0310 24 250 kSPS 1 Sigma-Delta ±10V, ±5V, 0V to +10V  54 mW SPI   59.00
CN0251 24 4.7 Hz 4 Sigma-Delta ±10V, ±5V, ±1V, ±500mV, ±250mV, ±125mV, ±62,5mV, ±31.25mV 130 mW SPI   80.00
CN0277 18 5 MSPS 1 PulSAR 0 V to +5 V 122 mW LVDS Optimized for AC Performance 99.00
CN0269 18 1.33 MSPS 16 PulSAR ±10V, ±5V
337 mW SPI   100.00
CN0261 18 250 kSPS 1 PulSAR 0 V to +5 V 107 mW SPI Optimized for AC Performance 79.00
CN0305 16 300 kSPS 1 PulSAR 0 V to +5 V 11 mW SPI Optimized for Sub-Nyquist Input Signals Up to 4 kHz 99.00
CN0254 16 250 kSPS 8 PulSAR ±10V 294 mW SPI Isolated 75.00
CN0306 16 100 kSPS 1 PulSAR 0 V to +5 V 7.4 mW SPI Optimized for Sub-Nyquist Input Signals Up to 4 kHz 99.00
CN0255 16 100 kSPS 1 PulSAR 0 V to +2.5 V 8 mW SPI 79.00
An additional evaluation control board is required for all Circuits from the Lab reference designs listed in the above table.