type: Analog Component
title: "DS18B20 — Programmable Resolution 1-Wire Digital Thermometer"
description: "Programmable Resolution 1-Wire Digital Thermometer"
resource: "https://www.analog.com/en/products/ds18b20.html"
tags: ["datasheet"]
status: draft
sources:
  - id: "datasheet"
    resource: "https://www.analog.com/media/en/technical-documentation/data-sheets/ds18b20.pdf"
    title: "DS18B20 data sheet"
    author: "team:analog-devices"
    last_modified: "7/19"
tables:
  - file: "ds18b20/tables/table-01-p2-spec.csv"
    title: "DC Electrical Characteristics"
    page: 2
  - file: "ds18b20/tables/table-02-p3-spec.csv"
    title: "AC Electrical Characteristics–NV Memory"
    page: 3
  - file: "ds18b20/tables/table-03-p3-spec.csv"
    title: "AC Electrical Characteristics"
    page: 3
  - file: "ds18b20/tables/table-04-p4-pin.csv"
    title: "Pin Description"
    page: 4
  - file: "ds18b20/tables/table-05-p6-data.csv"
    title: "Table 1. Temperature/Data Relationship"
    page: 6
  - file: "ds18b20/tables/table-06-p9-register.csv"
    title: "Table 2. Thermometer Resolution Configuration"
    page: 9
  - file: "ds18b20/tables/table-07-p12-data.csv"
    title: "Table 3. DS18B20 Function Command Set"
    page: 12
  - file: "ds18b20/tables/table-08-p18-data.csv"
    title: "DS18B20 Operation Example 1"
    page: 18
  - file: "ds18b20/tables/table-09-p18-data.csv"
    title: "DS18B20 Operation Example 2"
    page: 18
  - file: "ds18b20/tables/table-10-p19-data.csv"
    title: "Ordering Information"
    page: 19
  - file: "ds18b20/tables/table-11-p20-data.csv"
    title: "Revision History"
    page: 20
  - file: "ds18b20/tables/table-00-p2-abs_max.csv"
    title: "Absolute Maximum Ratings"
    page: 2
figures:
  - file: "ds18b20/figures/ds18b20-fig004.png"
    caption: "Figure 4. Temperature Register Format Table 1. Temperature/Data Relationship"
    type: "figure"
    page: 6
  - file: "ds18b20/figures/ds18b20-fig005.png"
    caption: "Figure 5. T_{H} and T_{L} Register Format"
    type: "figure"
    page: 6
  - file: "ds18b20/figures/ds18b20-fig008.png"
    caption: "Figure 8. 64-Bit Lasered ROM Code"
    type: "figure"
    page: 8
  - file: "ds18b20/figures/ds18b20-fig010.png"
    caption: "Figure 10. Configuration Register Table 2. Thermometer Resolution Configuration"
    type: "figure"
    page: 9
  - file: "ds18b20/figures/ds18b20-f000.png"
    caption: ""
    type: "pinout"
    page: 1
  - file: "ds18b20/figures/ds18b20-f002.png"
    caption: "Figure 1. Typical Performance Curve"
    type: "characteristic_curve"
    page: 3
  - file: "ds18b20/figures/ds18b20-f003.png"
    caption: "Figure 2. Timing Diagrams"
    type: "timing_diagram"
    page: 4
  - file: "ds18b20/figures/ds18b20-f004.png"
    caption: "Figure 3. DS18B20 Block Diagram"
    type: "block_diagram"
    page: 5
  - file: "ds18b20/figures/ds18b20-f005.png"
    caption: "Figure 6. Supplying the Parasite-Powered DS18B20 During Temperature Conversions"
    type: "application_circuit"
    page: 7
  - file: "ds18b20/figures/ds18b20-f006.png"
    caption: "Figure 7. Powering the DS18B20 with an External Supply"
    type: "application_circuit"
    page: 7
  - file: "ds18b20/figures/ds18b20-f007.png"
    caption: "Figure 9. DS18B20 Memory Map"
    type: "other"
    page: 8
  - file: "ds18b20/figures/ds18b20-f008.png"
    caption: "Figure 11. CRC Generator"
    type: "block_diagram"
    page: 9
  - file: "ds18b20/figures/ds18b20-f009.png"
    caption: "Figure 12. Hardware Configuration"
    type: "block_diagram"
    page: 10
  - file: "ds18b20/figures/ds18b20-f010.png"
    caption: "Figure 13. ROM Commands Flowchart"
    type: "other"
    page: 13
  - file: "ds18b20/figures/ds18b20-f011.png"
    caption: "Figure 14. DS18B20 Function Commands Flowchart"
    type: "other"
    page: 14
  - file: "ds18b20/figures/ds18b20-f012.png"
    caption: "Figure 15. Initialization Timing"
    type: "timing_diagram"
    page: 15
  - file: "ds18b20/figures/ds18b20-f013.png"
    caption: "Figure 16. Read/Write Time Slot Timing Diagram"
    type: "timing_diagram"
    page: 16
  - file: "ds18b20/figures/ds18b20-f014.png"
    caption: "Figure 17. Detailed Master Read 1 Timing"
    type: "timing_diagram"
    page: 17
  - file: "ds18b20/figures/ds18b20-f015.png"
    caption: "Figure 18. Recommended Master Read 1 Timing"
    type: "timing_diagram"
    page: 17
  - file: "ds18b20/figures/ds18b20-eq01.png"
    caption: "Equation as printed (p. 9)"
    type: equation
    page: 9
curves:
  - file: "ds18b20/curves/typical-performance-curve.csv"
    caption: "Figure 1. Typical Performance Curve"
    figure: "ds18b20/figures/ds18b20-f002.png"
    page: 3
    x_unit: "°C"
    y_unit: "°C"
agentforge:
  part_number: "DS18B20"
  datasheet_revision: "6"
  repairs: 2
  reading_order: "geometry"
---

# DS18B20 — Programmable Resolution 1-Wire Digital Thermometer

*Datasheet: [DS18B20 data sheet (PDF)](https://www.analog.com/media/en/technical-documentation/data-sheets/ds18b20.pdf)*

### General Description

The  DS18B20  digital  thermometer  provides  9-bit  to 12-bit  Celsius  temperature  measurements  and  has  an alarm function with nonvolatile user-programmable upper and  lower  trigger  points.  The  DS18B20  communicates over  a  1-Wire  bus  that  by  definition  requires  only  one data line (and ground) for communication with a central microprocessor.  In  addition,  the  DS18B20  can  derive power  directly  from  the  data  line  ('parasite  power'), eliminating the need for an external power supply.

Each  DS18B20  has  a  unique  64-bit  serial  code,  which allows multiple DS18B20s to function on the same 1-Wire bus.  Thus,  it  is  simple  to  use  one  microprocessor  to control  many  DS18B20s  distributed  over  a  large  area. Applications  that  can  benefit  from  this  feature  include HVAC  environmental  controls,  temperature  monitoring systems inside buildings,  equipment,  or  machinery,  and process monitoring and control systems.

### Applications

- Thermostatic Controls
- Industrial Systems
- Consumer Products
- Thermometers
- Thermally Sensitive Systems

### Benefits and Features

- Unique 1-Wire®  Interface Requires Only One Port Pin for Communication
- Reduce Component Count with Integrated Temperature Sensor and EEPROM
- Measures Temperatures from -55°C to +125°C (-67°F to +257°F)
- ±0.5°C Accuracy from -10°C to +85°C
- Programmable Resolution from 9 Bits to 12 Bits
- No External Components Required
- Parasitic Power Mode Requires Only 2 Pins for Operation (DQ and GND)
- Simplifies Distributed Temperature-Sensing Applications with Multidrop Capability
  - Each Device Has a Unique 64-Bit Serial Code Stored in On-Board ROM
- Flexible User-Definable Nonvolatile (NV) Alarm Settings with Alarm Search Command Identifies Devices with Temperatures Outside Programmed Limits
- Available in 8-Pin SO (150 mils), 8-Pin µSOP, and 3-Pin TO-92 Packages

### Pin Configurations

![pinout (p. 1)](ds18b20/figures/ds18b20-f000.png)

Ordering Information appears at end of data sheet.

1-Wire is a registered trademark of Maxim Integrated Products, Inc.

### Absolute Maximum Ratings

**Absolute Maximum Ratings** — [table-00-p2-abs_max.csv](ds18b20/tables/table-00-p2-abs_max.csv), p. 2

| PARAMETER | RATING |  |  |  |  |  |
|---|---|:---:|:---:|:---:|:---:|:---:|
| Voltage Range on Any Pin Relative to   Ground | -0.5V to +6.0V |  |  |  |  |  |
| Operating Temperature Range | -55°C to +125°C |  |  |  |  |  |
| Storage Temperature Range | -55°C to +125°C |  |  |  |  |  |
| Solder Temperature | Refer to the IPC/JEDEC J-STD-020 Specification.

These are stress ratings only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.

### DC Electrical Characteristics

(-55°C to +125°C; V_{DD} = 3.0V to 5.5V)

**DC Electrical Characteristics** ([table-01-p2-spec.csv](ds18b20/tables/table-01-p2-spec.csv), p. 2)

| PARAMETER | SYMBOL | CONDITIONS | MIN | TYP | MAX | UNITS |
|---|---|---|---|---|---|---|
| Supply Voltage | V_{DD} | Local power (Note 1) | +3.0 |  | +5.5 | V |
| Pullup Supply Voltage | V_{PU} | Parasite power (Notes 1, 2) | +3.0 |  | +5.5 | V |
| Pullup Supply Voltage | V_{PU} | Local power (Notes 1, 2) | +3.0 |  | V_{DD} | V |
| Thermometer Error | t_{ERR} | -10°C to +85°C (Note 3) |  |  | ±0.5 | °C |
| Thermometer Error | t_{ERR} | -30°C to +100°C (Note 3) |  |  | ±1 | °C |
| Thermometer Error | t_{ERR} | -55°C to +125°C (Note 3) |  |  | ±2 | °C |
| Input Logic-Low | V_{IL} | (Notes 1, 4, 5) | -0.3 |  | +0.8 | V |
| Input Logic-High | V_{IH} | Local power (Notes 1,6) | +2.2 |  | The lower of 5.5 or V_{DD} + 0.3 | V |
| Input Logic-High | V_{IH} | Parasite power (Notes 1,6) | +3.0 |  | The lower of 5.5 or V_{DD} + 0.3 | V |
| Sink Current | I_{L} | V_{I/O} = 0.4V | 4.0 |  |  | mA |
| Standby Current | I_{DDS} | (Notes 7, 8) |  | 750 | 1000 | nA |
| Active Current | I_{DD} | V_{DD} = 5V (Note 9) |  | 1 | 1.5 | mA |
| DQ Input Current | I_{DQ} | (Note 10) |  | 5 |  | µA |
| Drift |  | (Note 11) |  | ±0.2 |  | °C |

- **Note 1:** All voltages are referenced to ground.
- **Note 2:** The Pullup Supply Voltage specification assumes that the pullup device is ideal, and therefore the high level of the pullup is equal to V_{PU} . In order to meet the V_{IH} spec of the DS18B20, the actual supply rail for the strong pullup transistor must include margin for the voltage drop across the transistor when it is turned on; thus: V_{PU_ACTUAL} = V_{PU_IDEAL} + V_{TRANSISTOR}.
- **Note 3:** See typical performance curve in Figure 1. Thermometer Error limits are 3-sigma values. 
- **Note 4:** Logic-low voltages are specified at a sink current of 4mA.
- **Note 5:** To guarantee a presence pulse under low voltage parasite power conditions, V_{ILMAX} may have to be reduced to as low as 0.5V.
- **Note 6:** Logic-high voltages are specified at a source current of 1mA.
- **Note 7:** Standby current specified up to +70°C. Standby current typically is 3µA at +125°C.
- **Note 8:** To minimize I_{DDS} , DQ should be within the following ranges: GND ≤ DQ ≤ GND + 0.3V or  V_{DD} - 0.3V ≤ DQ ≤ V_{DD}.
- **Note 9:** Active current refers to supply current during active temperature conversions or EEPROM writes.
- **Note 10:** DQ line is high ("high-Z" state).
- **Note 11:** Drift data is based on a 1000-hour stress test at +125°C with V_{DD} = 5.5V.

### AC Electrical Characteristics-NV Memory

(-55°C to +125°C; V_{DD} = 3.0V to 5.5V)

**AC Electrical Characteristics–NV Memory** ([table-02-p3-spec.csv](ds18b20/tables/table-02-p3-spec.csv), p. 3)

| PARAMETER | SYMBOL | CONDITIONS | MIN | TYP | MAX | UNITS |
|---|---|---|---|---|---|---|
| NV Write Cycle Time | t_{WR} |  |  | 2 | 10 | ms |
| EEPROM Writes | N_{EEWR} | -55°C to +55°C | 50k |  |  | writes |
| EEPROM Data Retention | t_{EEDR} | -55°C to +55°C | 10 |  |  | years |

### AC Electrical Characteristics

(-55°C to +125°C; V_{DD} = 3.0V to 5.5V)

**AC Electrical Characteristics** ([table-03-p3-spec.csv](ds18b20/tables/table-03-p3-spec.csv), p. 3)

| PARAMETER | SYMBOL | CONDITIONS | MIN | TYP | MAX | UNITS |
|---|---|---|---|---|---|---|
| Temperature Conversion Time | t_{CONV} | 9-bit resolution (Note 12) |  |  | 93.75 | ms |
| Temperature Conversion Time | t_{CONV} | 10-bit resolution (Note 12) |  |  | 187.5 | ms |
| Temperature Conversion Time | t_{CONV} | 11-bit resolution (Note 12) |  |  | 375 | ms |
| Temperature Conversion Time | t_{CONV} | 12-bit resolution (Note 12) |  |  | 750 | ms |
| Time to Strong Pullup On | t_{SPON} | Start convert T command issued |  |  | 10 | µs |
| Time Slot | t_{SLOT} | (Note 12) | 60 |  | 120 | µs |
| Recovery Time | t_{REC} | (Note 12) | 1 |  |  | µs |
| Write 0 Low Time | t_{LOW0} | (Note 12) | 60 |  | 120 | µs |
| Write 1 Low Time | t_{LOW1} | (Note 12) | 1 |  | 15 | µs |
| Read Data Valid | t_{RDV} | (Note 12) |  |  | 15 | µs |
| Reset Time High | t_{RSTH} | (Note 12) | 480 |  |  | µs |
| Reset Time Low | t_{RSTL} | (Notes 12, 13) | 480 |  |  | µs |
| Presence-Detect High | t_{PDHIGH} | (Note 12) | 15 |  | 60 | µs |
| Presence-Detect Low | t_{PDLOW} | (Note 12) | 60 |  | 240 | µs |
| Capacitance | C_{IN/OUT} |  |  |  | 25 | pF |

- **Note 12:** See the timing diagrams in Figure 2.
- **Note 13:** Under parasite power, if t_{RSTL} > 960µs, a power-on reset can occur.

![Figure 1. Typical Performance Curve](ds18b20/figures/ds18b20-f002.png)

*Figure 1. Typical Performance Curve*

Digitized data: [typical-performance-curve.csv](ds18b20/curves/typical-performance-curve.csv) (x: °C; y: °C) — values read off the printed plot by the digitizer, not published data.

![Figure 2. Timing Diagrams](ds18b20/figures/ds18b20-f003.png)

*Figure 2. Timing Diagrams*

### Pin Description

**Pin Description** ([table-04-p4-pin.csv](ds18b20/tables/table-04-p4-pin.csv), p. 4)

| PIN | NAME | FUNCTION |
|---|---|---|
| SO: 1, 2, 6, 7, 8; µSOP: 2, 3, 5, 6, 7; TO-92: — | N.C. | No Connection |
| SO: 3; µSOP: 8; TO-92: 3 | V_{DD} | Optional V_{DD}. V_{DD} must be grounded for operation in parasite power mode. |
| SO: 4; µSOP: 1; TO-92: 2 | DQ | Data Input/Output. Open-drain 1-Wire interface pin. Also provides power to the device when used in parasite power mode (see the Powering the DS18B20 section.) |
| SO: 5; µSOP: 4; TO-92: 1 | GND | Ground |

### Overview

Figure  3  shows  a  block  diagram  of  the  DS18B20,  and pin  descriptions  are  given  in  the Pin  Description table. The 64-bit ROM stores the device's unique serial code. The scratchpad memory contains the 2-byte temperature register that stores the digital output from the temperature sensor. In addition, the scratchpad provides access to the 1-byte  upper  and  lower  alarm  trigger  registers  (T_{H} and TL ) and the 1-byte configuration register. The configuration  register  allows  the  user  to  set  the  resolution  of  the temperature-to-digital conversion to 9, 10, 11, or 12 bits. The  T_{H} ,  T_{L} ,  and  configuration  registers  are  nonvolatile (EEPROM), so they will retain  data  when  the  device  is powered down.

The DS18B20 uses Maxim's exclusive 1-Wire bus protocol that implements bus communication using one control signal.  The  control  line  requires  a  weak  pullup  resistor since  all  devices  are  linked  to  the  bus  via  a  3-state  or open-drain port (the DQ pin in the case of the DS18B20). In  this  bus  system,  the  microprocessor  (the  master device)  identifies  and  addresses  devices  on  the  bus using  each  device's  unique  64-bit  code.  Because  each device  has  a  unique  code,  the  number  of  devices  that can be addressed on one bus is virtually unlimited. The 1-Wire bus protocol, including detailed explanations of the commands and "time slots," is covered in the 1-Wire Bus System section.

Another  feature  of  the  DS18B20  is  the  ability  to  operate  without  an  external  power  supply.  Power  is  instead supplied  through  the  1-Wire  pullup  resistor  through  the DQ pin when the bus is high. The high bus signal also charges an internal capacitor (C_{PP} ), which then supplies power to the device when the bus is low. This method of deriving power from the 1-Wire bus is referred to as "parasite power." As an alternative, the DS18B20 may also be powered by an external supply on V_{DD} .

### Operation-Measuring Temperature

The  core  functionality  of  the  DS18B20  is  its  direct-todigital temperature sensor. The resolution of the temperature sensor is user-configurable to 9, 10, 11, or 12 bits, corresponding to increments of 0.5°C, 0.25°C, 0.125°C, and  0.0625°C,  respectively.  The  default  resolution  at power-up  is  12-bit.  The  DS18B20  powers  up  in  a  lowpower idle state. To initiate a temperature measurement and A-to-D conversion, the master must issue a Convert T [44h] command. Following the conversion, the resulting thermal data is stored in the 2-byte temperature register in the scratchpad memory and the DS18B20 returns to its idle state. If the DS18B20 is powered by an external supply, the master can issue "read time slots" (see the 1-Wire Bus System section) after the Convert T command and the DS18B20 will respond by transmitting 0 while the temperature conversion is in progress and 1 when the conversion is done. If the DS18B20 is powered with parasite power,  this  notification  technique  cannot  be  used  since the bus must be pulled high by a strong pullup during the entire temperature conversion. The bus requirements for parasite power are explained in detail in the Powering the DS18B20 section.

![Figure 3. DS18B20 Block Diagram](ds18b20/figures/ds18b20-f004.png)

*Figure 3. DS18B20 Block Diagram*

The  DS18B20  output  temperature  data  is  calibrated  in degrees  Celsius;  for  Fahrenheit  applications,  a  lookup table or conversion routine must be used. The temperature data is stored as a 16-bit sign-extended two's complement number in the temperature register (see Figure 4). The  sign  bits  (S)  indicate  if  the  temperature  is  positive or negative: for positive numbers S = 0 and for negative numbers S = 1. If the DS18B20 is configured for 12-bit resolution, all bits in the temperature register will contain valid  data.  For  11-bit  resolution,  bit  0  is  undefined.  For 10-bit resolution, bits 1 and 0 are undefined, and for 9-bit resolution  bits  2,  1,  and  0  are  undefined.  Table  1  gives examples  of  digital  output  data  and  the  corresponding temperature reading for 12-bit resolution conversions.

### Operation-Alarm Signaling

After  the  DS18B20  performs  a  temperature  conversion, the  temperature  value  is  compared  to  the  user-defined two's  complement  alarm  trigger  values  stored  in  the 1-byte T_{H} and T_{L} registers (see Figure 5). The sign bit (S) indicates if the value is positive or negative: for positive numbers S = 0 and for negative numbers S = 1. The T_{H} and T_{L} registers are nonvolatile (EEPROM) so they will retain data when the device is powered down. T_{H} and T_{L} can be accessed through bytes 2 and 3 of the scratchpad as explained in the Memory section.

Only  bits  11  through  4  of  the  temperature  register  are used in the T_{H} and T_{L} comparison since T_{H} and T_{L} are 8-bit registers. If the measured temperature is lower than

![Figure 4. Temperature Register Format Table 1. Temperature/Data Relationship](ds18b20/figures/ds18b20-fig004.png)

*Figure 4. Temperature Register Format*

### Table 1. Temperature/Data Relationship

**Table 1. Temperature/Data Relationship** ([table-05-p6-data.csv](ds18b20/tables/table-05-p6-data.csv), p. 6)

| TEMPERATURE (°C) | DIGITAL OUTPUT (BINARY) | DIGITAL OUTPUT (HEX) |
|---|---|---|
| +125 | 0000 0111 1101 0000 | 07D0h |
| +85* | 0000 0101 0101 0000 | 0550h |
| +25.0625 | 0000 0001 1001 0001 | 0191h |
| +10.125 | 0000 0000 1010 0010 | 00A2h |
| +0.5 | 0000 0000 0000 1000 | 0008h |
| 0 | 0000 0000 0000 0000 | 0000h |
| -0.5 | 1111 1111 1111 1000 | FFF8h |
| -10.125 | 1111 1111 0101 1110 | FF5Eh |
| -25.0625 | 1111 1110 0110 1111 | FE6Fh |
| -55 | 1111 1100 1001 0000 | FC90h |

- **\*:** The power-on reset value of the temperature register is +85°C.

![Figure 5. T_{H} and T_{L} Register Format](ds18b20/figures/ds18b20-fig005.png)

*Figure 5. T_{H} and T_{L} Register Format*

or equal to T_{L} or higher than or equal to T_{H} , an alarm condition exists and an alarm flag is set inside the DS18B20. This  flag  is  updated  after  every  temperature  measurement; therefore, if the alarm condition goes away, the flag will be turned off after the next temperature conversion.

The  master  device  can  check  the  alarm  flag  status  of all  DS18B20s  on  the  bus  by  issuing  an  Alarm  Search [ECh] command. Any DS18B20s with a set alarm flag will respond to the command, so the master can determine exactly  which  DS18B20s  have  experienced  an  alarm condition. If  an  alarm  condition  exists  and  the T_{H} or T_{L} settings have changed, another temperature conversion should be done to validate the alarm condition.

### Powering the DS18B20

The DS18B20 can be powered by an external supply on the V_{DD} pin, or it can operate in "parasite power" mode, which  allows  the  DS18B20  to  function  without  a  local external supply. Parasite power is very useful for applications that require remote temperature sensing or that are very space constrained. Figure 3 shows the DS18B20's parasite-power control circuitry, which "steals" power from the 1-Wire bus via the DQ pin when the bus is high. The stolen charge powers the DS18B20 while the bus is high, and some of the charge is stored on the parasite power capacitor  (C_{PP} )  to  provide  power  when  the  bus  is  low. When the DS18B20 is used in parasite power mode, the VDD pin must be connected to ground.

In parasite power mode, the 1-Wire bus and CPP can provide sufficient current to the DS18B20 for most operations as long as the specified timing and voltage requirements are  met  (see  the DC  Electrical  Characteristics and AC Electrical Characteristics ).  However, when the DS18B20 is  performing  temperature  conversions  or  copying  data from the scratchpad memory to EEPROM, the operating current can be as high as 1.5mA. This current can cause an  unacceptable  voltage  drop  across  the  weak  1-Wire pullup resistor and is more current than can be supplied by C_{PP} . To assure that the DS18B20 has sufficient supply current, it is necessary to provide a strong pullup on the 1-Wire  bus  whenever  temperature  conversions  are  taking place or data is being copied from the scratchpad to EEPROM. This can be accomplished by using a MOSFET to pull the bus directly to the rail as shown in Figure 6. The 1-Wire bus must be switched to the strong pullup within 10µs (max) after a Convert T [44h] or Copy Scratchpad [48h] command is issued, and the bus must be held high by the pullup for the duration of the conversion (t_{CONV} ) or data transfer (t_{WR}  = 10ms). No other activity can take place on the 1-Wire bus while the pullup is enabled.

The DS18B20 can also be powered by the conventional method  of  connecting  an  external  power  supply  to  the V_{DD}  pin,  as  shown  in  Figure  7.  The  advantage  of  this method is that the MOSFET pullup is not required, and the 1-Wire bus is free to carry other traffic during the temperature conversion time.

The use of parasite power is not recommended for temperatures above +100°C since the DS18B20 may not be able  to  sustain  communications  due  to  the  higher  leakage  currents  that  can  exist  at  these  temperatures.  For applications  in  which  such  temperatures  are  likely,  it  is strongly recommended that the DS18B20 be powered by an external power supply.

In some situations the bus master may not know whether the DS18B20s on the bus are parasite powered or powered by external supplies. The master needs this information to determine if the strong bus pullup should be used during temperature conversions. To get this information, the  master  can  issue  a  Skip  ROM  [CCh]  command  followed by a Read Power Supply [B4h] command followed by a "read time slot". During the read time slot, parasite powered DS18B20s will pull the bus low, and externally powered  DS18B20s  will  let  the  bus  remain  high.  If  the bus is pulled low, the master knows that it must supply the strong pullup on the 1-Wire bus during temperature conversions.

![Figure 6. Supplying the Parasite-Powered DS18B20 During Temperature Conversions](ds18b20/figures/ds18b20-f005.png)

*Figure 6. Supplying the Parasite-Powered DS18B20 During Temperature Conversions*

![Figure 7. Powering the DS18B20 with an External Supply](ds18b20/figures/ds18b20-f006.png)

*Figure 7. Powering the DS18B20 with an External Supply*

### 64-BIT Lasered ROM code

Each DS18B20 contains a unique 64-bit code (see Figure 8) stored in ROM. The least significant 8 bits of the ROM code contain the DS18B20's 1-Wire family code: 28h. The next  48  bits  contain  a  unique  serial  number.  The  most significant 8 bits contain a cyclic redundancy check (CRC) byte that is calculated from the first 56 bits of the ROM code. A detailed explanation of the CRC bits is provided in the CRC Generation section. The 64-bit ROM code and associated ROM function control logic allow the DS18B20 to operate as a 1-Wire device using the protocol detailed in the 1-Wire Bus System section.

### Memory

The DS18B20's memory is organized as shown in Figure 9.  The  memory  consists  of  an  SRAM  scratchpad  with nonvolatile EEPROM storage for the high and low alarm trigger  registers  (T_{H} and  T_{L} )  and  configuration  register. Note  that  if  the  DS18B20  alarm  function  is  not  used, the  TH  and  TL  registers  can  serve  as  general-purpose memory. All memory commands are described in detail in the DS18B20 Function Commands section.

Byte 0 and byte 1 of the scratchpad contain the LSB and the MSB of the temperature register, respectively. These bytes are read-only. Bytes 2 and 3 provide access to TH and TL registers. Byte 4 contains the configuration register data, which is explained in detail in the Configuration Register section. Bytes 5, 6, and 7 are reserved for internal use by the device and cannot be overwritten.

Byte  8  of  the  scratchpad  is  read-only  and  contains  the CRC  code  for  bytes  0  through  7  of  the  scratchpad. The  DS18B20  generates  this  CRC  using  the  method described in the CRC Generation section.

Data is written to bytes 2, 3, and 4 of the scratchpad using the Write Scratchpad [4Eh] command; the data must be transmitted to the DS18B20 starting with the least significant bit of byte 2. To verify data integrity, the scratchpad can be read (using the Read Scratchpad [BEh] command) after  the  data  is  written.  When  reading  the  scratchpad, data is transferred over the 1-Wire bus starting with the least significant bit of byte 0. To transfer the T_{H} , T_{L} and configuration data from the scratchpad to EEPROM, the master must issue the Copy Scratchpad [48h] command.

Data  in  the  EEPROM  registers  is  retained  when  the device is powered down; at power-up the EEPROM data is reloaded into the corresponding scratchpad locations. Data can also be reloaded from EEPROM to the scratchpad at any time using the Recall E^{2}  [B8h] command. The master can issue read time slots following the Recall E^{2} command and the DS18B20 will indicate the status of the recall by transmitting 0 while the recall is in progress and 1 when the recall is done.

![Figure 8. 64-Bit Lasered ROM Code](ds18b20/figures/ds18b20-fig008.png)

*Figure 8. 64-Bit Lasered ROM Code*

| 8-BIT CRC   | 8-BIT CRC   | 48-BIT SERIAL NUMBER   | 48-BIT SERIAL NUMBER   | 8-BIT FAMILY CODE (28h)   | 8-BIT FAMILY CODE (28h)   |
|-------------|-------------|------------------------|------------------------|---------------------------|---------------------------|
| MSB         | LSB         | MSB                    | LSB                    | MSB                       | LSB                       |

![Figure 9. DS18B20 Memory Map](ds18b20/figures/ds18b20-f007.png)

*Figure 9. DS18B20 Memory Map*

### Configuration Register

Byte 4 of the scratchpad memory contains the configuration register, which is organized as illustrated in Figure 10. The user can set the conversion resolution of the DS18B20 using the R0 and R1 bits in this register as shown in Table 2. The power-up default of these bits is R0 = 1 and R1 = 1  (12-bit  resolution).  Note  that  there  is  a  direct  tradeoff between resolution and conversion time. Bit 7 and bits 0 to 4 in the configuration register are reserved for internal use by the device and cannot be overwritten.

### CRC Generation

CRC bytes are provided as part of the DS18B20's 64-bit ROM code and in the 9^{th}  byte of the scratchpad memory. The ROM code CRC is calculated from the first 56 bits of the ROM code and is contained in the most significant byte of the ROM. The scratchpad CRC is calculated from the data stored in the scratchpad, and therefore it changes when the data in the scratchpad changes. The CRCs provide the bus master with a method of data validation when data is read from the DS18B20. To verify that data has been read correctly, the bus master must re-calculate the CRC from the received data and then compare this value to either the ROM code CRC (for ROM reads) or to the scratchpad CRC (for scratchpad reads). If the calculated CRC matches the read CRC, the data has been received error free. The comparison of CRC values and the decision to continue with an operation are determined entirely by the bus master. There is no circuitry inside the DS18B20 that prevents a command sequence from proceeding if the DS18B20 CRC (ROM or scratchpad) does not match the value generated by the bus master. 

The equivalent polynomial function of the CRC (ROM or scratchpad) is:

![Equation as printed (p. 9)](ds18b20/figures/ds18b20-eq01.png)

$$CRC = X^{8} + X^{5} + X^{4} + 1$$

*LaTeX transcription of the equation above, checked against the symbols printed on the page.*

The bus master can re-calculate the CRC and compare it to the CRC values from the DS18B20 using the polynomial  generator  shown in Figure 11. This circuit consists of  a  shift  register  and  XOR gates, and the shift register bits are initialized to 0. Starting with the least significant bit of the ROM code or the least significant bit of byte 0 in the scratchpad, one bit at a time should shifted into the shift register. After shifting in the 56th bit from the ROM or the most significant bit of byte 7 from the scratchpad, the polynomial generator will contain the recalculated CRC. Next,  the  8-bit  ROM  code  or  scratchpad  CRC  from  the DS18B20 must be shifted into the circuit. At this point, if the re-calculated CRC was correct, the shift register will contain  all  0s.  Additional  information  about  the  Maxim 1-Wire cyclic redundancy check is available in Application Note  27:  Understanding  and  Using  Cyclic  Redundancy Checks with Maxim iButton Products.

![Figure 10. Configuration Register Table 2. Thermometer Resolution Configuration](ds18b20/figures/ds18b20-fig010.png)

*Figure 10. Configuration Register*

### Table 2. Thermometer Resolution Configuration

**Table 2. Thermometer Resolution Configuration** ([table-06-p9-register.csv](ds18b20/tables/table-06-p9-register.csv), p. 9)

| R1 | R0 | RESOLUTION (BITS) | MAX CONVERSION TIME |
|---|---|---|---|
| 0 | 0 | 9 | 93.75ms (t_{CONV}/8) |
| 0 | 1 | 10 | 187.5ms (t_{CONV}/4) |
| 1 | 0 | 11 | 375ms (t_{CONV}/2) |
| 1 | 1 | 12 | 750ms (t_{CONV}) |

![Figure 11. CRC Generator](ds18b20/figures/ds18b20-f008.png)

*Figure 11. CRC Generator*

### 1-Wire Bus System

The 1-Wire bus system uses a single bus master to control one or more slave devices. The DS18B20 is always a slave. When there is only one slave on the bus, the system is referred to as a "single-drop" system; the system is "multidrop" if there are multiple slaves on the bus.

All  data  and commands are transmitted least significant bit first over the 1-Wire bus.

The  following  discussion  of  the  1-Wire  bus  system  is broken  down  into  three  topics:  hardware  configuration, transaction sequence, and 1-Wire signaling (signal types and timing).

### Hardware Configuration

The 1-Wire bus has by definition only a single data line. Each device (master or slave) interfaces to the data line via an open-drain or 3-state port. This allows each device to "release" the data line when the device is not transmitting data so the bus is available for use by another device. The  1-Wire  port  of  the  DS18B20  (the  DQ  pin)  is  open drain with an internal circuit equivalent to that shown in Figure 12

The  1-Wire  bus  requires  an  external  pullup  resistor  of approximately  5kΩ;  thus,  the  idle  state  for  the  1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus MUST be left in the idle state if the transaction is to resume. Infinite recovery time can occur between bits so long as the 1-Wire bus is in the inactive (high) state during the recovery period. If the bus is held low for more than 480µs, all components on the bus will be reset.

![Figure 12. Hardware Configuration](ds18b20/figures/ds18b20-f009.png)

*Figure 12. Hardware Configuration*

### Transaction Sequence

The transaction sequence for accessing the DS18B20 is as follows:

Step 1.  Initialization

Step 2.  ROM Command (followed by any required data exchange)

Step 3.  DS18B20 Function Command (followed by any required data exchange)

It is very important to follow this sequence every time the DS18B20 is accessed, as the DS18B20 will not respond if any steps in the sequence are missing or out of order. Exceptions  to  this  rule  are  the  Search  ROM  [F0h]  and Alarm  Search  [ECh]  commands.  After  issuing  either  of these ROM commands, the master must return to Step 1 in the sequence.

### Initialization

All transactions on the 1-Wire bus begin with an initialization  sequence. The initialization  sequence  consists  of  a reset  pulse  transmitted  by  the  bus  master  followed  by presence pulse(s) transmitted by the slave(s). The presence pulse lets the bus master know that slave devices (such  as  the  DS18B20)  are  on  the  bus  and  are  ready to  operate. Timing for  the  reset  and  presence  pulses  is detailed in the 1-Wire Signaling section.

### ROM Commands

After  the  bus  master  has  detected  a  presence  pulse,  it can issue a ROM command. These commands operate on  the  unique  64-bit  ROM  codes  of  each  slave  device and  allow  the  master  to  single  out  a  specific  device  if many are present on the 1-Wire bus. These commands also allow the master to determine how many and what types of devices are present on the bus or if any device has experienced an alarm condition. There are five ROM commands, and each command is 8 bits long. The master device must issue an appropriate ROM command before issuing  a  DS18B20  function  command.  A  flowchart  for operation of the ROM commands is shown in Figure 13.

### Search Rom [F0h]

When a system is initially powered up, the master must identify the ROM codes of all slave devices on the bus, which  allows  the  master  to  determine  the  number  of slaves  and  their  device  types.  The  master  learns  the ROM codes through a process of elimination that requires the master to perform a Search ROM cycle (i.e., Search ROM  command  followed  by  data  exchange)  as  many times  as  necessary  to  identify  all  of  the  slave  devices.

If  there  is  only  one  slave  on  the  bus,  the  simpler  Read ROM [33h] command can be used in place of the Search ROM process. For a detailed explanation of the Search ROM procedure, refer to Application Note 937: Book of iButton® Standards . After every Search ROM cycle, the bus  master  must  return  to  Step  1  (Initialization)  in  the transaction sequence.

### Read Rom [33h]

This command can only be used when there is one slave on the bus. It allows the bus master to read the slave's 64-bit ROM code without using the Search ROM procedure. If  this  command is used when there is more than one slave present on the bus, a data collision will occur when all the slaves attempt to respond at the same time.

### Match Rom [55H]

The  match  ROM  command  followed  by  a  64-bit  ROM code  sequence  allows  the  bus  master  to  address  a specific  slave  device  on  a  multidrop  or  single-drop  bus. Only the slave that exactly matches the 64-bit ROM code sequence will  respond  to  the  function  command  issued by the master; all other slaves on the bus will wait for a reset pulse.

### Skip Rom [CCh]

The master can use this command to address all devices on the bus simultaneously without sending out any ROM code information. For example, the master can make all DS18B20s on the bus perform simultaneous temperature conversions by issuing a Skip ROM command followed by a Convert T [44h] command.

Note  that  the  Read  Scratchpad  [BEh]  command  can follow  the  Skip  ROM  command only if  there  is  a  single slave  device  on  the  bus.  In  this  case,  time  is  saved  by allowing the master to read from the slave without sending the device's 64-bit ROM code. A Skip ROM command followed  by  a  Read  Scratchpad  command  will  cause a  data  collision  on  the  bus  if  there  is  more  than  one slave since multiple devices will attempt to transmit data simultaneously.

### Alarm Search [ECh]

The operation of this command is identical to the operation of the Search ROM command except that only slaves with a set alarm flag will respond. This command allows the master device to determine if any DS18B20s experienced an  alarm  condition  during  the  most  recent  temperature conversion. After  every Alarm  Search  cycle  (i.e., Alarm Search  command  followed  by  data  exchange),  the  bus master must return to Step 1 (Initialization) in the transaction sequence. See the Operation-Alarm Signaling section for an explanation of alarm flag operation.

### DS18B20 Function Commands

After  the  bus  master  has  used  a  ROM  command  to address the DS18B20 with which it wishes to communicate, the master can issue one of the DS18B20 function commands. These commands allow the master to write to  and  read  from  the  DS18B20's  scratchpad  memory, initiate temperature conversions and determine the power supply mode. The DS18B20 function commands, which are described below, are summarized in Table 3 and illustrated by the flowchart in Figure 14.

### Convert T [44h]

This command initiates a single temperature conversion. Following  the  conversion,  the  resulting  thermal  data  is stored in the 2-byte temperature register in the scratchpad memory and the DS18B20 returns to its low-power idle  state.  If  the  device  is  being  used  in  parasite  power mode,  within  10µs  (max)  after  this  command  is  issued the master must enable a strong pullup on the 1-Wire bus for  the  duration  of  the  conversion (t_{CONV}) as described in the Powering the DS18B20 section. If the DS18B20 is powered by an external supply, the master can issue read time slots after the Convert T command and the DS18B20 will  respond  by  transmitting  a  0  while  the  temperature conversion is in progress and a 1 when the conversion is done. In parasite power mode this notification technique cannot be used since the bus is pulled high by the strong pullup during the conversion.

### Write Scratchpad [4Eh]

This command allows the master to write 3 bytes of data to the DS18B20's scratchpad. The first data byte is written into the T_{H} register (byte 2 of the scratchpad), the second byte is written into the T_{L} register (byte 3), and the third byte is written into the configuration register (byte 4). Data must  be  transmitted  least  significant  bit  first.  All  three bytes MUST be written before the master issues a reset, or the data may be corrupted.

### Read Scratchpad [BEh]

This command allows the master to read the contents of the scratchpad. The data transfer starts with the least significant bit of byte 0 and continues through the scratchpad until the 9th byte (byte 8 - CRC) is read. The master may issue a reset to terminate reading at any time if only part of the scratchpad data is needed.

iButton is a registered trademark of Maxim Integrated Products, Inc.

### Copy Scratchpad [48h]

This  command  copies  the  contents  of  the  scratchpad T_{H}, T_{L} and configuration registers (bytes 2, 3 and 4) to EEPROM. If the device is being used in parasite power mode, within 10µs (max) after this command is issued the master must enable a strong pullup on the 1-Wire bus for at least 10ms as described in the Powering the DS18B20 section.

### Recall E^{2} [B8h]

This command recalls the alarm trigger values (T_{H} and T_{L} ) and configuration data from EEPROM and places the data in bytes 2, 3, and 4, respectively, in the scratchpad memory.  The  master  device  can  issue  read  time  slots following the Recall E^{2}  command and the DS18B20 will indicate the status of the recall by transmitting 0 while the recall is in progress and 1 when the recall is done. The recall  operation  happens  automatically  at  power-up,  so valid data is available in the scratchpad as soon as power is applied to the device.

### Read Power Supply [B4h]

The  master  device  issues  this  command  followed  by  a read time slot to determine if any DS18B20s on the bus are using parasite power. During the read time slot, parasite powered DS18B20s will pull the bus low, and externally powered DS18B20s will let the bus remain high. See the Powering the DS18B20 section for usage information for this command.

**Table 3. DS18B20 Function Command Set** ([table-07-p12-data.csv](ds18b20/tables/table-07-p12-data.csv), p. 12)

| COMMAND | DESCRIPTION | PROTOCOL | 1-Wire BUS ACTIVITY AFTER COMMAND IS ISSUED | NOTES |
|---|---|---|---|---|
| **TEMPERATURE CONVERSION COMMANDS** |  |  |  |  |
| Convert T | Initiates temperature conversion. | 44h | DS18B20 transmits conversion status to master (not applicable for parasite-powered DS18B20s). | 1 |
| **MEMORY COMMANDS** |  |  |  |  |
| Read Scratchpad | Reads the entire scratchpad including the CRC byte. | BEh | DS18B20 transmits up to 9 data bytes to master. | 2 |
| Write Scratchpad | Writes data into scratchpad bytes 2, 3, and 4 (T_{H}, T_{L}, and configuration registers). | 4Eh | Master transmits 3 data bytes to DS18B20. | 3 |
| Copy Scratchpad | Copies T_{H}, T_{L}, and configuration register data from the scratchpad to EEPROM. | 48h | None | 1 |
| Recall E^{2} | Recalls T_{H}, T_{L}, and configuration register data from EEPROM to the scratchpad. | B8h | DS18B20 transmits recall status to master. |  |
| Read Power Supply | Signals DS18B20 power supply mode to the master. | B4h | DS18B20 transmits supply status to master. |  |

- **Note 1:** For parasite-powered DS18B20s, the master must enable a strong pullup on the 1-Wire bus during temperature conversions and copies from the scratchpad to EEPROM. No other bus activity may take place during this time.
- **Note 2:** The master can interrupt the transmission of data at any time by issuing a reset.
- **Note 3:** All three bytes must be written before a reset is issued.

![Figure 13. ROM Commands Flowchart](ds18b20/figures/ds18b20-f010.png)

*Figure 13. ROM Commands Flowchart*

![Figure 14. DS18B20 Function Commands Flowchart](ds18b20/figures/ds18b20-f011.png)

*Figure 14. DS18B20 Function Commands Flowchart*

### 1-Wire Signaling

The  DS18B20  uses  a  strict  1-Wire  communication  protocol  to  ensure  data  integrity.  Several  signal  types  are defined by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. The bus master initiates all these signals, with the exception of the presence pulse.

### Initialization Procedure-Reset And Presence Pulses

All communication with the DS18B20 begins with an initialization sequence that consists of a reset pulse from the master followed by a presence pulse from the DS18B20. This is illustrated in Figure 15. When the DS18B20 sends the presence pulse in response to the reset, it is indicating to the master that it is on the bus and ready to operate.

During the initialization  sequence  the  bus  master  transmits  (T_{X}) the  reset  pulse  by  pulling  the  1-Wire  bus  low for  a  minimum of 480µs. The bus master then releases the bus and goes into receive mode (R_{X}). When the bus is released, the 5kΩ pullup resistor pulls the 1-Wire bus high. When the DS18B20 detects this rising edge, it waits 15µs to 60µs and then transmits a presence pulse by pulling the 1-Wire bus low for 60µs to 240µs.

### Read/Write Time Slots

The bus master writes data to the DS18B20 during write time slots and reads data from the DS18B20 during read time slots. One bit of data is transmitted over the 1-Wire bus per time slot.

### Write Time Slots

There are two types of write time slots: "Write 1" time slots and "Write 0" time slots. The bus master uses a Write 1 time slot to write a logic 1 to the DS18B20 and a Write 0  time  slot  to  write  a  logic  0  to  the  DS18B20. All  write time slots must be a minimum of 60µs in duration with a minimum of a 1µs recovery time between individual write slots.  Both  types  of  write  time  slots  are  initiated  by  the master pulling the 1-Wire bus low (see Figure 14).

To generate a Write 1 time slot, after pulling the 1-Wire bus  low,  the  bus  master  must  release  the  1-Wire  bus within  15µs.  When  the  bus  is  released,  the  5kΩ  pullup resistor will pull the bus high. To generate a Write 0 time slot, after pulling the 1-Wire bus low, the bus master must continue to hold the bus low for the duration of the time slot (at least 60µs).

The DS18B20 samples the 1-Wire bus during a window that lasts from 15µs to 60µs after the master initiates the write time slot. If the bus is high during the sampling window, a 1 is written to the DS18B20. If the line is low, a 0 is written to the DS18B20.

![Figure 15. Initialization Timing](ds18b20/figures/ds18b20-f012.png)

*Figure 15. Initialization Timing*

![Figure 16. Read/Write Time Slot Timing Diagram](ds18b20/figures/ds18b20-f013.png)

*Figure 16. Read/Write Time Slot Timing Diagram*

### Read Time Slots

The DS18B20 can only transmit data to the master when the master issues read time slots. Therefore, the master must generate read time slots immediately after issuing a  Read  Scratchpad  [BEh]  or  Read  Power  Supply  [B4h] command, so that the DS18B20 can provide the requested data. In addition, the master can generate read time slots after issuing Convert T [44h] or Recall E^{2}  [B8h] commands to find out the status of the operation as explained in the DS18B20 Function Commands section.

All read time slots must be a minimum of 60µs in duration with a minimum of a 1µs recovery time between slots. A read time slot is initiated by the master device pulling the 1-Wire bus low for a minimum of 1µs and then releasing the  bus  (see  Figure  16).  After  the  master  initiates  the read  time  slot,  the  DS18B20  will  begin  transmitting  a  1 or 0 on bus. The DS18B20 transmits a 1 by leaving the bus high and transmits a 0 by pulling the bus low. When transmitting a 0, the DS18B20 will release the bus by the end of the time slot, and the bus will be pulled back to its high idle state by the pullup resister. Output data from the DS18B20 is valid for 15µs after the falling edge that initiated  the  read  time  slot.  Therefore,  the  master  must release  the  bus  and  then  sample  the  bus  state  within 15µs from the start of the slot.

Figure  17  illustrates  that  the  sum  of  T_{INIT} ,  T_{RC} ,  and T_{SAMPLE} must be less  than  15µs  for  a  read  time  slot. Figure 18 shows that system timing margin is maximized by  keeping T_{INIT} and T_{RC} as  short  as  possible  and  by locating  the  master  sample  time  during  read  time  slots towards the end of the 15µs period.

![Figure 17. Detailed Master Read 1 Timing](ds18b20/figures/ds18b20-f014.png)

*Figure 17. Detailed Master Read 1 Timing*

![Figure 18. Recommended Master Read 1 Timing](ds18b20/figures/ds18b20-f015.png)

*Figure 18. Recommended Master Read 1 Timing*

### Related Application Notes

The following application notes can be applied to the DS18B20 and are available at www.maximintegrated.com .

Application  Note  27:  Understanding  and  Using  Cyclic Redundancy Checks with Maxim iButton Products

Application Note 122: Using Dallas' 1-Wire ICs in 1-Cell Li-Ion  Battery  Packs  with  Low-Side  N-Channel  Safety FETs Master

Application  Note  126:  1-Wire  Communication  Through Software

Application  Note  162:  Interfacing  the  DS18x20/DS1822 1-Wire Temperature Sensor in a Microcontroller Environment

Application  Note  208:  Curve  Fitting  the  Error  of  a Bandgap-Based Digital Temperature Sensor

Application  Note  2420:  1-Wire  Communication  with  a Microchip PICmicro Microcontroller

Application  Note  3754:  Single-Wire  Serial  Bus  Carries Isolated Power and Data

Sample 1-Wire subroutines that can be used in conjunction with Application Note 74: Reading and Writing iButtons  via  Serial  Interfaces can  be  downloaded  from  the Maxim website.

### DS18B20 Operation Example 1

In this example there are multiple DS18B20s on the bus and they are using parasite power. The bus master initiates a temperature conversion in a specific DS18B20 and then  reads  its  scratchpad  and  recalculates  the  CRC  to verify the data.

**DS18B20 Operation Example 1** ([table-08-p18-data.csv](ds18b20/tables/table-08-p18-data.csv), p. 18)

| MASTER MODE | DATA (LSB FIRST) | COMMENTS |
|---|---|---|
| Tx | Reset | Master issues reset pulse. |
| Rx | Presence | DS18B20s respond with presence pulse. |
| Tx | 55h | Master issues Match ROM command. |
| Tx | 64-bit ROM code | Master sends DS18B20 ROM code. |
| Tx | 44h | Master issues Convert T command. |
| Tx | DQ line held high by strong pullup | Master applies strong pullup to DQ for the duration of the conversion (t_{CONV}). |
| Tx | Reset | Master issues reset pulse. |
| Rx | Presence | DS18B20s respond with presence pulse. |
| Tx | 55h | Master issues Match ROM command. |
| Tx | 64-bit ROM code | Master sends DS18B20 ROM code. |
| Tx | BEh | Master issues Read Scratchpad command. |
| Rx | 9 data bytes | Master reads entire scratchpad including CRC. The master then recalculates the CRC of the first eight data bytes from the scratchpad and compares the calculated CRC with the read CRC (byte 9). If they match, the master continues; if not, the read operation is repeated. |

### DS18B20 Operation Example 2

In this example there is only one DS18B20 on the bus and it is using parasite power. The master writes to the TH, TL, and  configuration  registers  in  the  DS18B20  scratchpad and then reads the scratchpad and recalculates the CRC to verify the data. The master then copies the scratchpad contents to EEPROM.

**DS18B20 Operation Example 2** ([table-09-p18-data.csv](ds18b20/tables/table-09-p18-data.csv), p. 18)

| MASTER MODE | DATA (LSB FIRST) | COMMENTS |
|---|---|---|
| Tx | Reset | Master issues reset pulse. |
| Rx | Presence | DS18B20 responds with presence pulse. |
| Tx | CCh | Master issues Skip ROM command. |
| Tx | 4Eh | Master issues Write Scratchpad command. |
| Tx | 3 data bytes | Master sends three data bytes to scratchpad (T_{H}, T_{L}, and config). |
| Tx | Reset | Master issues reset pulse. |
| Rx | Presence | DS18B20 responds with presence pulse. |
| Tx | CCh | Master issues Skip ROM command. |
| Tx | BEh | Master issues Read Scratchpad command. |
| Rx | 9 data bytes | Master reads entire scratchpad including CRC. The master then recalculates the CRC of the first eight data bytes from the scratchpad and compares the calculated CRC with the read CRC (byte 9). If they match, the master continues; if not, the read operation is repeated. |
| Tx | Reset | Master issues reset pulse. |
| Rx | Presence | DS18B20 responds with presence pulse. |
| Tx | CCh | Master issues Skip ROM command. |
| Tx | 48h | Master issues Copy Scratchpad command. |
| Tx | DQ line held high by strong pullup | Master applies strong pullup to DQ for at least 10ms while copy operation is in progress. |

### Ordering Information

**Ordering Information** ([table-10-p19-data.csv](ds18b20/tables/table-10-p19-data.csv), p. 19)

| PART | TEMP RANGE | PIN-PACKAGE | TOP MARK |
|---|---|---|---|
| DS18B20 | -55°C to +125°C | 3 TO-92 | 18B20 |
| DS18B20+ | -55°C to +125°C | 3 TO-92 | 18B20 |
| DS18B20/T&R | -55°C to +125°C | 3 TO-92 (2000 Piece) | 18B20 |
| DS18B20+T&R | -55°C to +125°C | 3 TO-92 (2000 Piece) | 18B20 |
| DS18B20-SL/T&R | -55°C to +125°C | 3 TO-92 (2000 Piece)* | 18B20 |
| DS18B20-SL+T&R | -55°C to +125°C | 3 TO-92 (2000 Piece)* | 18B20 |
| DS18B20U | -55°C to +125°C | 8 FSOP | 18B20 |
| DS18B20U+ | -55°C to +125°C | 8 FSOP | 18B20 |
| DS18B20U/T&R | -55°C to +125°C | 8 FSOP (3000 Piece) | 18B20 |
| DS18B20U+T&R | -55°C to +125°C | 8 FSOP (3000 Piece) | 18B20 |
| DS18B20Z | -55°C to +125°C | 8 SO | DS18B20 |
| DS18B20Z+ | -55°C to +125°C | 8 SO | DS18B20 |
| DS18B20Z/T&R | -55°C to +125°C | 8 SO (2500 Piece) | DS18B20 |
| DS18B20Z+T&R | -55°C to +125°C | 8 SO (2500 Piece) | DS18B20 |

- +: Denotes a lead-free package. A "+" will appear on the top mark of lead-free packages.
- T&R: = Tape and reel.
- **\*:** TO-92 packages in tape and reel can be ordered with straight or formed leads. Choose "SL" for straight leads. Bulk TO-92 orders are straight leads only.

### Revision History

**Revision History** ([table-11-p20-data.csv](ds18b20/tables/table-11-p20-data.csv), p. 20)

| REVISION DATE | DESCRIPTION | PAGES CHANGED |
|---|---|---|
| 3/1/07 | In the Absolute Maximum Ratings section, removed the reflow oven temperature value of +220°C. Reference to JEDEC specification for reflow remains. | 19 |
| 10/12/07 | In the Operation—Alarm Signaling section, added "or equal to" in the description for a TH alarm condition | 5 |
| 10/12/07 | In the Memory section, removed incorrect text describing memory. | 7 |
| 10/12/07 | In the Configuration Register section, removed incorrect text describing configuration register. | 8 |
| 4/22/08 | In the Ordering Information table, added TO-92 straight-lead packages and included a note that the TO-92 package in tape and reel can be ordered with either formed or straight leads. | 2 |
| 1/15 | Updated Benefits and Features section | 1 |
| 09/18 | Updated DC Electrical Characteristics table | 2 |
| 7/19 | Updated Figure 12 | 10 |