type: Analog Component
title: "ADMT4000 — True Power-On Multiturn Sensor"
description: "True Power-On Multiturn Sensor"
resource: "https://www.analog.com/en/products/admt4000.html"
tags: ["datasheet", "adi"]
status: draft
sources:
  - id: "datasheet"
    resource: "https://www.analog.com/media/en/technical-documentation/data-sheets/admt4000.pdf"
    title: "ADMT4000 data sheet"
    author: "team:analog-devices"
tables:
  - file: "admt4000/tables/table-00-p3-spec.csv"
    title: "Table 1. Electrical Characteristics"
    page: 3
  - file: "admt4000/tables/table-01-p5-spec.csv"
    title: "Table 2. Diagnostics Fault Conditions"
    page: 5
  - file: "admt4000/tables/table-02-p6-spec.csv"
    title: "Table 3. SPI Timing Specifications"
    page: 6
  - file: "admt4000/tables/table-03-p8-abs_max.csv"
    title: "Table 4. Absolute Maximum Ratings"
    page: 8
  - file: "admt4000/tables/table-04-p8-data.csv"
    title: "Table 5. Thermal Resistance"
    page: 8
  - file: "admt4000/tables/table-05-p8-data.csv"
    title: "Table 6. ESD Ratings for ADMT4000"
    page: 8
  - file: "admt4000/tables/table-06-p10-pin.csv"
    title: "Table 7. Pin Function Descriptions"
    page: 10
  - file: "admt4000/tables/table-17-p30-register.csv"
    title: "Table 18. Bit Description for the TMP Register"
    page: 30
  - file: "admt4000/tables/table-18-p30-register.csv"
    title: "Table 19. Bit Description for the GENERAL Register"
    page: 30
  - file: "admt4000/tables/table-07-p19-data.csv"
    title: "Table 8. SINE and COSINE Calculation from the AMR Bridge Measurements"
    page: 19
  - file: "admt4000/tables/table-08-p25-register.csv"
    title: "Table 9. Register Map Summary"
    page: 25
  - file: "admt4000/tables/table-09-p26-register.csv"
    title: "Table 10. Bit Description for the CNVPAGE Register"
    page: 26
  - file: "admt4000/tables/table-10-p26-register.csv"
    title: "Table 11. Bit Description for the ABSANGLE Register"
    page: 26
  - file: "admt4000/tables/table-11-p27-register.csv"
    title: "Table 12. Bits Description for the DIGIO Register"
    page: 27
  - file: "admt4000/tables/table-12-p27-register.csv"
    title: "Table 13. Bit Description for the ANGLE Register"
    page: 27
  - file: "admt4000/tables/table-13-p27-register.csv"
    title: "Table 14. Bit Description for the FAULT Register"
    page: 27
  - file: "admt4000/tables/table-14-p29-register.csv"
    title: "Table 15. Bit Description for the SINE Register"
    page: 29
  - file: "admt4000/tables/table-15-p29-register.csv"
    title: "Table 16. Bit Description for the COSINE Register"
    page: 29
  - file: "admt4000/tables/table-16-p29-register.csv"
    title: "Table 17. Bit Description for the RADIUS Register"
    page: 29
  - file: "admt4000/tables/table-19-p31-register.csv"
    title: "Table 20. Bit Description for the DIGIOEN Register"
    page: 31
  - file: "admt4000/tables/table-20-p32-register.csv"
    title: "Table 21. Bit Description for the CNVCNT Register"
    page: 32
  - file: "admt4000/tables/table-21-p32-register.csv"
    title: "Table 22. Bit Description for the H1MAG Register"
    page: 32
  - file: "admt4000/tables/table-22-p32-register.csv"
    title: "Table 23. Bit Description for the H1PH Register"
    page: 32
  - file: "admt4000/tables/table-23-p33-register.csv"
    title: "Table 24. Bit Description for the H2MAG Register"
    page: 33
  - file: "admt4000/tables/table-24-p33-register.csv"
    title: "Table 25. Bit Description for the H2PH Register"
    page: 33
  - file: "admt4000/tables/table-25-p33-register.csv"
    title: "Table 26. Bit Description for the H3MAG Register"
    page: 33
  - file: "admt4000/tables/table-26-p34-register.csv"
    title: "Table 27. Bit Description for the H3PH Register"
    page: 34
  - file: "admt4000/tables/table-27-p34-register.csv"
    title: "Table 28. Bit Description for the H8MAG Register"
    page: 34
  - file: "admt4000/tables/table-28-p34-register.csv"
    title: "Table 29. Bit Description for the H8PH Register"
    page: 34
  - file: "admt4000/tables/table-29-p35-register.csv"
    title: "Table 30. Bit Description for the ECCEDC Register"
    page: 35
  - file: "admt4000/tables/table-30-p35-register.csv"
    title: "Table 31. Bit Description for the UNIQID0 Register"
    page: 35
  - file: "admt4000/tables/table-31-p35-register.csv"
    title: "Table 32. Bit Description for the UNIQID1 Register"
    page: 35
  - file: "admt4000/tables/table-32-p36-register.csv"
    title: "Table 33. Bit Description for the UNIQID2 Register"
    page: 36
  - file: "admt4000/tables/table-33-p36-register.csv"
    title: "Table 34. Bit Description for the UNIQID3 Register"
    page: 36
  - file: "admt4000/tables/table-34-p36-register.csv"
    title: "Table 35. Bit Description for the ECCDIS Register"
    page: 36
  - file: "admt4000/tables/table-35-p40-data.csv"
    title: "Table 36. Ordering Guide"
    page: 40
figures:
  - file: "admt4000/figures/admt4000-f001.png"
    caption: ""
    type: "other"
    page: 1
  - file: "admt4000/figures/admt4000-f002.png"
    caption: "Figure 1. Functional Block Diagram"
    type: "block_diagram"
    page: 1
  - file: "admt4000/figures/admt4000-f003.png"
    caption: "Figure 2. SPI Controller Request Timing Diagram"
    type: "timing_diagram"
    page: 7
  - file: "admt4000/figures/admt4000-f004.png"
    caption: "Figure 3. SPI Timing Diagram for Subordinate Response"
    type: "timing_diagram"
    page: 7
  - file: "admt4000/figures/admt4000-f006.png"
    caption: "Figure 4. ADMT4000 PIN CONFIGURATION"
    type: "pinout"
    page: 10
  - file: "admt4000/figures/admt4000-f007.png"
    caption: "Figure 5. Supply Current in Continuous Conversion Mode vs. Ambient Temperature"
    type: "characteristic_curve"
    page: 12
  - file: "admt4000/figures/admt4000-f008.png"
    caption: "Figure 6. Supply Current in One-Shot Mode when not Sampling vs. Ambient Temperature"
    type: "characteristic_curve"
    page: 12
  - file: "admt4000/figures/admt4000-f009.png"
    caption: "Figure 7. Temperature Sensor Error vs. Ambient Temperature"
    type: "characteristic_curve"
    page: 12
  - file: "admt4000/figures/admt4000-f010.png"
    caption: "Figure 8. Angular Measurement Noise at 3.3 V, 25 mT vs. Ambient Temperature"
    type: "characteristic_curve"
    page: 12
  - file: "admt4000/figures/admt4000-f011.png"
    caption: "Figure 9. Angle Measurement Accuracy vs. Operating Magnetic Flux Density at 3.3 V"
    type: "characteristic_curve"
    page: 12
  - file: "admt4000/figures/admt4000-f012.png"
    caption: "Figure 10. Functional Block Diagram"
    type: "block_diagram"
    page: 13
  - file: "admt4000/figures/admt4000-f013.png"
    caption: "Figure 11. Continuous Conversion Sampling Mode Showing an Abort Sequence and Reinitialization of the Measurement"
    type: "timing_diagram"
    page: 15
  - file: "admt4000/figures/admt4000-f014.png"
    caption: "Figure 13. Angle Measurements are Initiated in Synchronized Angle Mode by a Falling Edge on the C̅N̅V̅  Signal"
    type: "timing_diagram"
    page: 16
  - file: "admt4000/figures/admt4000-f015.png"
    caption: "Figure 12. One-Shot Conversion Sequence"
    type: "timing_diagram"
    page: 16
  - file: "admt4000/figures/admt4000-f016.png"
    caption: "Figure 14. Turn Count Behavior vs. Input Magnetic Field Angle"
    type: "characteristic_curve"
    page: 17
  - file: "admt4000/figures/admt4000-f017.png"
    caption: "Figure 15. IIR Transfer Function Used for the Angle Filter"
    type: "block_diagram"
    page: 18
  - file: "admt4000/figures/admt4000-f018.png"
    caption: "Figure 16. Resetting the GMR Turn Count Sensor by Applying an External Magnetic Field"
    type: "other"
    page: 19
  - file: "admt4000/figures/admt4000-f019.png"
    caption: "Figure 17. Sine and Cosine Signals from AMR Bridges of the Angle Sensor"
    type: "block_diagram"
    page: 19
  - file: "admt4000/figures/admt4000-f020.png"
    caption: "Figure 18. SPI Register Read Operation"
    type: "timing_diagram"
    page: 22
  - file: "admt4000/figures/admt4000-f021.png"
    caption: "Figure 19. 32-Bit Write Operation for 16-Bit Register"
    type: "timing_diagram"
    page: 22
  - file: "admt4000/figures/admt4000-f022.png"
    caption: "Figure 20. EV-ADMT4000SDV Evaluation Board in an End-of-Shaft Configuration"
    type: "other"
    page: 23
  - file: "admt4000/figures/admt4000-f023.png"
    caption: "Figure 21. Sensor Alignment Error"
    type: "other"
    page: 24
  - file: "admt4000/figures/admt4000-f024.png"
    caption: "Figure 22. Magnet Axis Displacement Error"
    type: "other"
    page: 24
  - file: "admt4000/figures/admt4000-f025.png"
    caption: "Figure 23. Magnetization Error"
    type: "other"
    page: 24
  - file: "admt4000/figures/admt4000-f026.png"
    caption: "Figure 24. Magnet Tilt Error"
    type: "other"
    page: 24
  - file: "admt4000/figures/admt4000-f027.png"
    caption: "Figure 25. Typical NdFeB Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor"
    type: "characteristic_curve"
    page: 37
  - file: "admt4000/figures/admt4000-f028.png"
    caption: "Figure 26. Typical SmCo Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor"
    type: "characteristic_curve"
    page: 38
  - file: "admt4000/figures/admt4000-f029.png"
    caption: "Figure 27. Minimum Magnetic Feld Strength on the GMR Turn Count Sensor vs. Error Rate"
    type: "characteristic_curve"
    page: 38
  - file: "admt4000/figures/admt4000-f030.png"
    caption: "Figure 28. Typical System Configuration for the Case where no GPIO Functions are Required"
    type: "application_circuit"
    page: 39
  - file: "admt4000/figures/admt4000-f031.png"
    caption: "Figure 29. Typical System Configuration for the Case where GPIO Functions are Required"
    type: "application_circuit"
    page: 39
  - file: "admt4000/figures/admt4000-f032.png"
    caption: ""
    type: "other"
    page: 40
  - file: "admt4000/figures/admt4000-f033.png"
    caption: "Figure 30. 24-Lead Thin Shrink Small-Outline Package [TSSOP]"
    type: "other"
    page: 40
  - file: "admt4000/figures/admt4000-f034.png"
    caption: ""
    type: "other"
    page: 40
  - file: "admt4000/figures/admt4000-f035.png"
    caption: ""
    type: "other"
    page: 40
  - file: "admt4000/figures/admt4000-eq02.png"
    caption: "Equation as printed (p. 30)"
    type: equation
    page: 30
  - file: "admt4000/figures/admt4000-eq01.png"
    caption: "Equation as printed (p. 17)"
    type: equation
    page: 17
curves:
  - file: "admt4000/curves/angle-measurement-accuracy-vs-operating-magnetic-flux-density-at-3-3-v.csv"
    caption: "Figure 9. Angle Measurement Accuracy vs. Operating Magnetic Flux Density at 3.3 V"
    figure: "admt4000/figures/admt4000-f011.png"
    page: 12
    x_unit: "mT"
    y_unit: "m°"
  - file: "admt4000/curves/angular-measurement-noise-at-3-3-v-25-mt-vs-ambient-temperature.csv"
    caption: "Figure 8. Angular Measurement Noise at 3.3 V, 25 mT vs. Ambient Temperature"
    figure: "admt4000/figures/admt4000-f010.png"
    page: 12
    x_unit: "°C"
    y_unit: "m°rms"
  - file: "admt4000/curves/minimum-magnetic-feld-strength-on-the-gmr-turn-count-sensor-vs-error-rate.csv"
    caption: "Figure 27. Minimum Magnetic Feld Strength on the GMR Turn Count Sensor vs. Error Rate"
    figure: "admt4000/figures/admt4000-f029.png"
    page: 38
    x_unit: "mT"
    y_unit: "ppm"
  - file: "admt4000/curves/supply-current-in-continuous-conversion-mode-vs-ambient-temperature.csv"
    caption: "Figure 5. Supply Current in Continuous Conversion Mode vs. Ambient Temperature"
    figure: "admt4000/figures/admt4000-f007.png"
    page: 12
    x_unit: "°C"
    y_unit: "mA"
  - file: "admt4000/curves/supply-current-in-one-shot-mode-when-not-sampling-vs-ambient-temperature.csv"
    caption: "Figure 6. Supply Current in One-Shot Mode when not Sampling vs. Ambient Temperature"
    figure: "admt4000/figures/admt4000-f008.png"
    page: 12
    x_unit: "°C"
    y_unit: "mA"
  - file: "admt4000/curves/temperature-sensor-error-vs-ambient-temperature.csv"
    caption: "Figure 7. Temperature Sensor Error vs. Ambient Temperature"
    figure: "admt4000/figures/admt4000-f009.png"
    page: 12
    x_unit: "°C"
    y_unit: "Degrees"
  - file: "admt4000/curves/turn-count-behavior-vs-input-magnetic-field-angle.csv"
    caption: "Figure 14. Turn Count Behavior vs. Input Magnetic Field Angle"
    figure: "admt4000/figures/admt4000-f016.png"
    page: 17
    x_unit: "Degrees"
    y_unit: "Degrees"
  - file: "admt4000/curves/typical-ndfeb-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-co.csv"
    caption: "Figure 25. Typical NdFeB Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor"
    figure: "admt4000/figures/admt4000-f027.png"
    page: 37
    x_unit: "°C"
    y_unit: "mT"
  - file: "admt4000/curves/typical-smco-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-cou.csv"
    caption: "Figure 26. Typical SmCo Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor"
    figure: "admt4000/figures/admt4000-f028.png"
    page: 38
    x_unit: "°C"
    y_unit: "mT"
agentforge:
  part_number: "ADMT4000"
  datasheet_revision: "C"
  repairs: 2
  reading_order: "structure-tree"
---

# ADMT4000 — True Power-On Multiturn Sensor

*Datasheet: [ADMT4000 data sheet (PDF)](https://www.analog.com/media/en/technical-documentation/data-sheets/admt4000.pdf)*

### FEATURES

- True power-on multiturn counter
- 46-turn magnetic sensor
- >16k° digital output
- ±0.25° accuracy
- Measurement update rate 100 kSPS
- 16 mT to 31 mT operating range
- Internal temperature sensor
- IC supply, 3.3 V
- SPI interface, 1.7 V to 5 V
- Junction temperature range: -40°C to +150°C
- 24-pin TSSOP
- Industrial applications

### APPLICATIONS

- Rotation count detection and storage without power
- Contactless absolute position measurement
- Brushless DC motor control and positioning
- Actuator control and positioning

### GENERAL DESCRIPTION

The ADMT4000 is a magnetic turn count sensor capable of recording the number of rotations of a magnetic system even while the device is powered down. On power-up, the device can be interrogated to report the absolute position of the system. The absolute position is reported through a serial-peripheral interface (SPI). The ADMT4000 counts up to 46-turns of an external magnetic field, which increments the absolute position in the clockwise (CW) direction.

The device includes three magnetic sensors, a giant magneto resistance (GMR) turn count sensor, which is used to count the number of rotations on the system, a GMR quadrant detecting sensor, and an anisotropic magnetoresistance (AMR) angle sensor. The AMR angle sensor is used in combination with a GMR quadrant detecting sensor to determine the absolute position of the system within 360°. Combining the GMR turn count sensor output with the AMR angle sensor output enables the device to report the position of the system with a high degree of angular accuracy.

### PRODUCT HIGHLIGHTS
- True power-on multiturn counter
- Angle sensor with ±0.25° accuracy
- SPI interface
- Under and over voltage detection

### FUNCTIONAL BLOCK DIAGRAM

![Figure 1. Functional Block Diagram](admt4000/figures/admt4000-f002.png)

*Figure 1. Functional Block Diagram*
### TABLE OF CONTENTS

- Features...1
- Application...1
- General Description...1
- Product Highlights...1
- Functional Block Diagram...1
- Table of Contents...2
- Revision History...2
- Specifications...3
  - Electrical Characteristics...3
  - Diagnostics Fault Conditions...5
  - SPI Timing Specifications...6
  - SPI Timing Diagrams...7
- Absolute Maximum Ratings...8
  - Thermal Resistance...8
  - ESD Ratings for ADMT4000...8
  - ESD Caution...9
- Pin Configuration and Function Descriptions...10
- Typical Performance Characteristics...12
- Theory of Operation...13
- Overview...13
- Sampling Modes...15
- Turn Count Behavior...16
- Angle Measurement Filter...17
- GMR Turn Count Sensor Reset...18
- Diagnostics and Fault Detection...19
- Serial-Peripheral Interface (SPI)...20
- Device Identification...22
- Calibration...23
- Register Details...25
- Page Agnostic Registers...26
- Page 0x0 Registers...28
- Page 0x2 Registers...30
- Applications...37
  - Rotational Speed Considerations...37
  - Magnet Considerations...37
  - Typical System Configuration...38
- Outline Dimensions...40
- Ordering Guide...40
- Notes...41

### REVISION HISTORY

Revision 0 | 10/2024  
Initial Version

Revision A | 11/2024  
Update to the ANGLE register definition

Revision B | 1/2026  
Update to the legend on Figure 8

Revision C | 7 /2026  
Update to Table 30

### SPECIFICATIONS

### Electrical Characteristics

V_{DD} = 3.3 V ± 10%, V_{SS} = 0 V, T_{J} = -40°C to +150°C, where T_{J} is the junction temperature.

**Table 1. Electrical Characteristics** ([table-00-p3-spec.csv](admt4000/tables/table-00-p3-spec.csv), p. 3)

| PARAMETER | CONDITIONS | MIN | TYP | MAX | UNITS |
|---|---|---|---|---|---|
| **MAGNETIC CHARACTERISTICS** |  |  |  |  |  |
| Turn-Count Detection Range |  | 0 |  | 46 | Turns |
| Angle Measurement Accuracy | Accuracy in a perfect magnetic system Measured at 25 mT | −0.90 | ±0.25 | +0.90 | Degrees |
| **Angle Measurement Noise[^1]** |  |  |  |  |  |
| IIR-Filter Disabled | Measured at 25°C, 25 mT |  |  | 0.25 | Degrees RMS |
| IIR-Filter Enabled | Measured at 25°C, 25 mT |  |  | 0.03 | Degrees RMS |
| **Magnetic Window** |  |  |  |  |  |
| Magnetic-Field Operating Window[^2] | Measured at 25°C, for more details, see the Magnet Considerations section | 16 |  | 31 | mT |
| T_{C} (B_{MAX}) |  |  | −0.050 |  | %K^{−1} |
| T_{C} (B_{MIN}) |  |  | −0.065 |  | %K^{−1} |
| **INTERNAL TEMPERATURE SENSOR** |  |  |  |  |  |
| Accuracy |  |  | ±5 |  | °C |
| Resolution |  |  | ±0.07 |  | °C |
| MEASUREMENT RATE |  |  | 100 |  | kSPS |
| **SAMPLE TIMING** |  |  |  |  |  |
| C̅N̅V̅ to Angle Sample | When configured to use an external convert start signal, the time between a falling edge on the C̅N̅V̅ pin and sampling instant of the SIN and COS inputs |  | 1 |  | µs |
| C̅N̅V̅ Pulse Width[^1] | The minimum time that C̅N̅V̅ must be at V_{IH} or above before initiating a conversion with a falling edge | 100 |  |  | ns |
| Convert Start Synchronization (CNVSYNC) | Minimum time between triggering new samples in CNVSYNC mode | 10 |  |  | µs |
| Start-Up Time | Time from V_{DD} above the minimum specified-voltage level to the time when bootload has completed |  |  | 10 | ms |
| **LOGIC SUPPLY** |  |  |  |  |  |
| V_{DRIVE} |  | 1.7 |  | 5.5 | V |
| **DIGITAL OUTPUTS** |  |  |  |  |  |
| **Output Voltage** |  |  |  |  |  |
| High, V_{OH} | 200 µA load | V_{DRIVE} × 0.9 |  |  | V |
| Low, V_{OL} | 200 µA load |  |  | 0.4 | V |
| Floating State-Leakage Current[^1] |  |  |  | 10 | µA |
| Floating State-Output Capacitance[^1], C_{OUT} |  |  | 5 |  | pF |
| **DIGITAL INPUTS** |  |  |  |  |  |
| Input Voltage[^1] |  |  |  |  |  |
| High, V_{IH} |  | V_{DRIVE} × 0.7 |  |  | V |
| Low, V_{IL} |  |  |  | V_{DRIVE} × 0.3 | V |
| Input Leakage Current, I_{IN} |  |  |  | ±10 | µA |
| Input Capacitance, C_{IN} |  |  | 5 |  | pF |
| **POWER SUPPLY** |  |  |  |  |  |
| Supply Voltage, V_{DD} |  | 3.0 | 3.3 | 3.6 | V |
| **Supply Current** |  |  |  |  |  |
| Zero Power Mode, I_{SY} | V_{DD} = 0 V, V_{DRIVE} = 0 V, and digital inputs = 0 V |  |  | 0 | nA |
| Active Mode, I_{SY} | Typical at V_{DD} = 3.3 V, T_{J} = 25°C |  | 18 | 22 | mA |
| Active Mode, I_{SY} | Typical at V_{DD} = 3.3 V, T_{J} = 25°C, and continuous conversion mode |  | 23 | 30 | mA |

- **Note 1:** Not production tested. Guaranteed by design and/or characterization.
- **Note 2:** The minimum magnetic field strength is defined as the magnetic field required to ensure an error rate of less than 1 ppm.

### Diagnostics Fault Conditions

V_{DD} = 3.3 V ± 10%, V_{SS} = 0 V, T_{J} = -40°C to +150°C, where T_{J} is the junction temperature.

**Table 2. Diagnostics Fault Conditions** ([table-01-p5-spec.csv](admt4000/tables/table-01-p5-spec.csv), p. 5)

| PARAMETER | CONDITIONS/ COMMENTS | MIN | TYP | MAX | UNIT |
|---|---|---|---|---|---|
| **DIAGNOSTICS FAULT CONDITIONS** |  |  |  |  |  |
| Angle Sensor Radius |  | 4352 |  | 23296 | Code (decimal) |
| **Power Supply** |  |  |  |  |  |
| V_{DD} Undervoltage |  |  | 3.0 |  | V |
| V_{DD} Overvoltage |  |  | 5.4 |  | V |
| V_{DRIVE} Undervoltage |  |  | 1.5 |  | V |
| V_{DRIVE} Overvoltage |  |  | 5.7 |  | V |



### SPI Timing Specifications

V_{DD} = 3.3 V ± 10%, V_{SS} = 0 V, T_{J} = -40°C to +150°C, where T_{J} is the junction temperature. Parameters are not production tested, guaranteed by design and/or characterization.

**Table 3. SPI Timing Specifications** ([table-02-p6-spec.csv](admt4000/tables/table-02-p6-spec.csv), p. 6)

| PARAMETER | CONDITIONS | MIN | TYP | MAX | UNITS |
|---|---|---|---|---|---|
| f_{SCLK} | SCLK frequency |  |  | 10 | MHz |
| t_{CSS} | C̅S̅ setup time[^1] | 0 |  |  | ns |
| t_{CSH} | C̅S̅ hold time[^1] | 0 |  |  | ns |
| t_{CSD} | C̅S̅ disable time[^1] | 0 |  |  | µs |
| t_{SU} | Data-setup time[^1] | 20 |  |  | ns |
| t_{HD} | Data-hold time[^1] | 20 |  |  | ns |
| t_{R} | SCLK rise time | 0 |  | 5 | ns |
| t_{F} | SCLK fall time | 0 |  | 5 | ns |
| t_{HIGH} | SCLK high time[^1] | 40 |  |  | ns |
| t_{LOW} | SCLK low time[^1] | 40 |  |  | ns |
| t_{CLD} | SCLK delay time[^1] | 10 |  |  | ns |
| t_{CLE} | SCLK enable time[^1] | 10 |  |  | ns |
| t_{V} | Output delay from SCLK low |  |  | 40 | ns |
| t_{HO} | Output hold time[^1] | 10 |  |  | ns |
| t_{DIS} | Output disable time[^1] |  |  | 5 | ns |

- **Note 1:** Timing is between the 50% V_{DRIVE} levels.

### SPI Timing Diagrams

![Figure 2. SPI Controller Request Timing Diagram](admt4000/figures/admt4000-f003.png)

*Figure 2. SPI Controller Request Timing Diagram*

![Figure 3. SPI Timing Diagram for Subordinate Response](admt4000/figures/admt4000-f004.png)

*Figure 3. SPI Timing Diagram for Subordinate Response*

### ABSOLUTE MAXIMUM RATINGS

**Table 4. Absolute Maximum Ratings** ([table-03-p8-abs_max.csv](admt4000/tables/table-03-p8-abs_max.csv), p. 8)

| PARAMETER | RATING |
|---|---|
| Magnetic Field Strength | 200 mT |
| V_{DD} to V_{SS} | −0.3 V to +6.0 V |
| Digital Input Voltage | −0.3 V to V_{DRIVE} + 0.3 V |
| Digital Output Voltage | −0.3 V to V_{DRIVE} + 0.3 V |
| V_{DRIVE} | −0.3 V to +6.0 V |
| TEST | −0.3 V to +0.3 V |
| DV18 | −0.3 V to +2.5 V |
| **Temperature** |  |
| Operating Junction, T_{J} | −40°C to +150°C |
| Storage | −55°C to +150°C |

Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability.

### Thermal Resistance

Thermal performance is directly linked to printed circuit board (PCB) design and operating environment. Careful attention to PCB thermal design is required. θ_{JA} is the natural convection junction-to-ambient thermal resistance measured in a one cubic foot sealed enclosure.

θ_{JC} is the junction-to-case thermal resistance. Thermal performance is defined by the JEDEC JESD-51 test specifications.

### Table 5. Thermal Resistance

**Table 5. Thermal Resistance** ([table-04-p8-data.csv](admt4000/tables/table-04-p8-data.csv), p. 8)

| Package Type | θ_{JA} | θ_{JC} | Unit |
|---|---|---|---|
| RU-24 | 73.25 | 17.56 | °C/W |

### ESD Ratings for ADMT4000

The following ESD information is provided for handling of ESD-sensitive devices in an ESD protected area only. Human body model (HBM) per ANSI/ESDA/JEDEC JS-001. Charged device model (CDM) per ANSI/ESDA/JEDEC JS-002.

### Table 6. ESD Ratings for ADMT4000

**Table 6. ESD Ratings for ADMT4000** ([table-05-p8-data.csv](admt4000/tables/table-05-p8-data.csv), p. 8)

| ESD Model | Withstand Threshold (V) | Class |
|---|---|---|
| HBM | ±2000 | 2 |
| CDM (on corner pins) | ±750 | C3 |
| CDM (on non-corner pins) | ±500 | C3 |

### ESD Caution

ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality.

### PIN CONFIGURATION AND FUNCTION DESCRIPTIONS

![Figure 4. ADMT4000 PIN CONFIGURATION](admt4000/figures/admt4000-f006.png)

*Figure 4. ADMT4000 PIN CONFIGURATION*

### NOTES

1. NC = NO CONNECT. THIS PIN IS NOT INTERNALLY CONNECTED AND SHOULD BE LEFT FLOATING OR CONNECTED TO GROUND.

2. TEST = MANUFACTURER TEST PIN. CONNECT TO GND.

**Table 7. Pin Function Descriptions** ([table-06-p10-pin.csv](admt4000/tables/table-06-p10-pin.csv), p. 10)

| NUMBER | NAME | TYPE | DESCRIPTION |
|---|---|---|---|
| 1 | DV18 |  | 1.8 V Regulator Decoupling. A 100 nF X8R capacitor to GND must be placed as close as possible to Pin 1. |
| 2 | GPIO3/ACALC |  | Digital Input and Output or Angle Calculation Status Output. Pin 2 is a dual-function pin. GPIO3 is a user-configurable digital input and output. ACALC is an output signal, which indicates when the angle is being calculated so the user can synchronize SPI angle read commands. By default, Pin 2 is configured as a digital input. If not used, this pin must be connected to GND through a 100 kΩ resistor. |
| 3 | GPIO4 |  | Digital Input and Output. Pin 3 is a user-configurable digital input and output. By default this pin is configured as a digital input. If not used, Pin 3 must be configured as an input and connected to GND through a 100 kΩ resistor. |
| 4 | GPIO5/BOOTLOAD |  | Digital Input and Output or Bootloader Status Output. Pin 4 is a dual-function pin. GPIO5 is a user-configurable digital input and output. The BOOTLOAD output function is configured by default and set high at power on. Once the bootload sequence has successfully completed, Pin 4 is set low. The user must connect Pin 4 to VDRIVE through a 100 kΩ resistor. |
| 5 | VDD |  | Positive Power-Supply Voltage. A 100 nF X8R and a 1 µF X8R capacitor must be placed in parallel to GND as close as possible to Pin 5. |
| 6 | GND |  | Negative Power-Supply Voltage. |
| 7 | GND |  | Negative Power-Supply Voltage. |
| 8 | TEST |  | Connect Pin 8 to GND. |
| 9 | TEST |  | Connect Pin 9 to GND. |
| 10 | TEST |  | Connect Pin 10 to GND. |
| 11 | NC |  | No Connect. This pin is not internally connected and should be left floating or connected to ground. |
| 12 | NC |  | No Connect. This pin is not internally connected and should be left floating or connected to ground. |
| 13 | NC |  | No Connect. This pin is not internally connected and should be left floating or connected to ground. |
| 14 | NC |  | No Connect. This pin is not internally connected and should be left floating or connected to ground. |
| 15 | SDO |  | Serial Data Output. A 100 kΩ resistor must be connected between the SDO pin and GND. |
| 16 | SDI |  | Serial Data Input. |
| 17 | SCLK |  | Serial Clock. |
| 18 | C̅S̅ |  | Chip-Select Signal (Active Low) to Frame the SDI. |
| 19 | GPIO0/BUSY |  | Digital Input and Output or Busy. Pin 19 is a dual-function pin. GPIO0 is a user-configurable digital input and output. BUSY is set high when the part is performing a measurement. By default, Pin 19 is configured as a digital input. If not used, Pin 19 must be connected to GND through a 100 kΩ resistor. |
| 20 | GPIO1/C̅N̅V̅ |  | Digital Input and Output or Convert Start. Pin 20 is a dual-function pin. GPIO1 is a user-configurable digital input and output. A falling edge on Pin 20 initiates a conversion when configured as the convert start pin C̅N̅V̅, and bits 15:14 of the Convert Start and Register Page Select register are set to 0b00. By default, Pin 20 is configured as a digital input. If not used, Pin 20 must be connected to GND through a 100 kΩ resistor. |
| 21 | VDRIVE |  | Logic Power-Supply Input. A 100 nF X8R capacitor to GND must be placed as close as possible to Pin 5. |
| 22 | R̅E̅S̅E̅T̅ |  | Reset. Taking Pin 22 low performs a reset of the digital and analog circuitry and does not reset the GMR turn count sensor element. If not used, Pin 22 must be connected to VDRIVE through a 100 kΩ resistor. |
| 23 | GPIO2 |  | Digital Input and Output. GPIO2 is a user-configurable digital input and output. By default, this pin is configured as a digital input. If not used, Pin 23 must be configured as an input and connected to GND through a 100 kΩ resistor. |
| 24 | NC |  | No Connect. This pin is not internally connected and should be left floating or connected to ground. |

### TYPICAL PERFORMANCE CHARACTERISTICS

![Figure 5. Supply Current in Continuous Conversion Mode vs. Ambient Temperature](admt4000/figures/admt4000-f007.png)

*Figure 5. Supply Current in Continuous Conversion Mode vs. Ambient Temperature*

Digitized data: [supply-current-in-continuous-conversion-mode-vs-ambient-temperature.csv](admt4000/curves/supply-current-in-continuous-conversion-mode-vs-ambient-temperature.csv) (x: °C; y: mA) — values read off the printed plot by the digitizer, not published data.

![Figure 6. Supply Current in One-Shot Mode when not Sampling vs. Ambient Temperature](admt4000/figures/admt4000-f008.png)

*Figure 6. Supply Current in One-Shot Mode when not Sampling vs. Ambient Temperature*

Digitized data: [supply-current-in-one-shot-mode-when-not-sampling-vs-ambient-temperature.csv](admt4000/curves/supply-current-in-one-shot-mode-when-not-sampling-vs-ambient-temperature.csv) (x: °C; y: mA) — values read off the printed plot by the digitizer, not published data.

![Figure 7. Temperature Sensor Error vs. Ambient Temperature](admt4000/figures/admt4000-f009.png)

*Figure 7. Temperature Sensor Error vs. Ambient Temperature*

Digitized data: [temperature-sensor-error-vs-ambient-temperature.csv](admt4000/curves/temperature-sensor-error-vs-ambient-temperature.csv) (x: °C; y: Degrees) — values read off the printed plot by the digitizer, not published data.

![Figure 8. Angular Measurement Noise at 3.3 V, 25 mT vs. Ambient Temperature](admt4000/figures/admt4000-f010.png)

*Figure 8. Angular Measurement Noise at 3.3 V, 25 mT vs. Ambient Temperature*

Digitized data: [angular-measurement-noise-at-3-3-v-25-mt-vs-ambient-temperature.csv](admt4000/curves/angular-measurement-noise-at-3-3-v-25-mt-vs-ambient-temperature.csv) (x: °C; y: m°rms) — values read off the printed plot by the digitizer, not published data.

![Figure 9. Angle Measurement Accuracy vs. Operating Magnetic Flux Density at 3.3 V](admt4000/figures/admt4000-f011.png)

*Figure 9. Angle Measurement Accuracy vs. Operating Magnetic Flux Density at 3.3 V*

Digitized data: [angle-measurement-accuracy-vs-operating-magnetic-flux-density-at-3-3-v.csv](admt4000/curves/angle-measurement-accuracy-vs-operating-magnetic-flux-density-at-3-3-v.csv) (x: mT; y: m°) — values read off the printed plot by the digitizer, not published data.

### THEORY OF OPERATION

### Overview

The ADMT4000 is a sensor that records the absolute position of an incident magnetic field over a maximum of 46 rotations, incrementing in the clockwise direction. When powered down, the sensor continues to track the rotational state of the magnetic field. When power is restored, the state of the sensors can be interrogated through the SPI interface.

The block diagram for the ADMT4000 is shown in Figure 10.

![Figure 10. Functional Block Diagram](admt4000/figures/admt4000-f012.png)

*Figure 10. Functional Block Diagram*

### GMR Turn Count Sensor

The magnetic multiturn technology is based on a spiral made of a ferromagnetic nanowire. A rotating magnetic field can cause a local change in magnetization enabled by magnetic domain walls propagating along the spiral. Since the nanowire is fabricated using a GMR stack, a propagating domain wall causes a resistance change. Small portions of the spiral resistances are measured to locate the domain walls. The number of turns a magnetic field has rotated can be determined by decoding the measured resistance pattern of the spiral.

### AMR Angle Sensor

The AMR angle sensor is formed by two sets of AMR elements. The resistance of each element varies with the direction of the external magnetic field. The AMR elements of each set are configured as a Wheatstone bridge offset by an angle of 45° so that the outputs are proportional to the sine and cosine of the direction of the external magnetic field. The sine output and the cosine output measure one full cycle for every 180° rotation of the external magnetic field.

### GMR Quadrant Sensor

The GMR quadrant sensor provides the information required to enable the 0° to 180° AMR angle sensor data to be extended to 360°.

### Temperature Sensor

To compensate for the temperature drift of the AMR angle sensor, an internal temperature sensor, TMP, is integrated into the part. Factory set calibration coefficients are applied. The temperature measurements are available through the TMP register using the SPI interface.

### Signal Conditioning

The outputs from the GMR turn count, GMR quadrant, and AMR angle sensors require conditioning to match the input requirements of the analog-to-digital converter (ADC). The turn count and quadrant sensors outputs are conditioned in the turn count channel analog front end (AFE) block. The AMR angle sensor outputs are conditioned with two sample-and-hold amplifiers (SHA). The SHAs are also used to enable simultaneous sampling of the two AMR angle sensor outputs to ensure phase alignment when measurements are taken in a rotating magnetic field.

### Analog-to-Digital Converter (ADC)

A single 12-bit successive approximation register (SAR) ADC using VDD as the reference is used to sample the GMR turn count sensor, AMR angle sensors, GMR quadrant detector, and some of the diagnostic features. Using VDD as the voltage reference for the ADC enables ratiometric measurements to be made, which optimizes performance across the voltage-supply ranges.

### System Oscillators

The oscillator, OSC, is used to provide the clock for the on-board logic and AFE.

### Control and Diagnostics

The core functionality of the device is determined by the control logic and diagnostics block. Key functions of the control logic include:

- Loading the factory set nonvolatile memory (NVM) into a series of volatile registers, which are used during the operation of the device. Factory set data includes calibration, device configuration, and identification data.
- Decoding the GMR turn count sensor elements to determine the turn count. A redundant turn count decoding block is included as a cross-check to the primary turn count decoder.
- Combining the outputs of the GMR turn count sensor, GMR quadrant detector, and AMR angle sensor to provide the absolute position of the system across a 0° to 16560° range, without further need for synchronization or data processing by the host system.
- On-chip harmonic calibration of the measured angle to provide the correction of system mechanical and magnet imperfections without the need for external processing. This calibration function enables system tolerances to be taken into account by compensating for first, second, and third harmonics when operating with the SPI interface. In addition, the use of the sensor in low field conditions can be optimized by updating the factory set eighth harmonic calibration to the specific operating environment.
- A state machine to control the measurement sequence of the GMR turn count sensor elements, GMR quadrant detector, AMR angle sensor, and diagnostics.
- Control of the sample acquisition mode, continuous or one-shot sampling.
- Enabling the angle measurement filter.

### Interface Logic

The SPI interface pins are powered by the VDRIVE supply, enabling the part to be paired with a wide variety of microprocessors. The SPI is a bidirectional interface, which gives access to the configuration and results registers of the device.

### Sampling Modes

It is possible to operate the device in either a continuous conversion mode or a one-shot conversion mode. In both modes, the sampling sequence is initiated by either writing to the CNVPAGE register or by using an external signal on the C̅N̅V̅ pin. An additional triggering mode, synchronized angle, can be used in a continuous sampling mode to synchronize the angle measurement with an external source.

### Continuous Conversion Mode

Following a device reset, Bit 0 (CNVMDE) of the General Register is set to zero to configure the device in the continuous conversion mode, and a conversion sequence is initiated. Conversion sequences repeat until the host system interrupts the sequence with a rising edge on C̅N̅V̅  (Pin 20) or an SPI write to Bits 15:14 of the Convert Start and Register Page Select register to 0b11. To reinitialize the conversion sequence, a convert-start signal must be generated. This is achieved with either a falling edge on the C̅N̅V̅  (Pin 20) or an SPI write to Bits 15:14 of the Convert Start and Register Page Select register to 0b00. By default, Pin 20 is configured as digital input, to make use of Pin 20 for convert-start control, the user must configure DIGIO register. If Pin 20 is configured as the C̅N̅V̅  input, Bits 15:14 of the Convert Start and Register Page Select register are disabled.

As shown in Figure 11, if configured, the BUSY (Pin 19) remains high until the continuous conversion mode is aborted or paused. The turn count becomes valid at the end of the first conversion sequence. The turn count Absolute Angle Register is updated once an angle measurement has been completed within the conversion sequence.

The ACALC (Pin 2) is set high when the part is calculating the current angle and is set low once the angle has been calculated and the angle register updated, as shown in Figure 11.

![Figure 11. Continuous Conversion Sampling Mode Showing an Abort Sequence and Reinitialization of the Measurement](admt4000/figures/admt4000-f013.png)

*Figure 11. Continuous Conversion Sampling Mode Showing an Abort Sequence and Reinitialization of the Measurement*

### One-Shot Conversion Mode

By default, and following a reset, the device is in a continuous conversion mode. The user must set Bit 0 (CNVMDE) high in the General Register to configure the device to operate in the one-shot mode. The conversion sequence is initiated either by a falling edge of a signal applied to the C̅N̅V̅  (Pin 20) or by setting Bits 15:14 (C̅N̅V̅ ) of the Convert Start and Register Page Select register to 0b00. To make use of an external convert start signal, the C̅N̅V̅ pin must be configured in the Digital Input/Output Enable Register (Bit 1). The Convert Start and Register Page Select register cannot be used to generate the convert-start signal once Pin 20 has been configured in this way.

As shown in Figure 12, the BUSY (Pin 19) remains high until the conversion sequence is complete and the angle registers have been updated. The turn count and angle are available once the conversion sequence has completed as indicated by the falling edge of the BUSY signal.

![Figure 12. One-Shot Conversion Sequence](admt4000/figures/admt4000-f015.png)

*Figure 12. One-Shot Conversion Sequence*

### Synchronized Angle

An optional sampling mode, CNVSYNC, is available to enable the angle measurements to be synchronized within a conversion sequence with an external C̅N̅V̅  signal.

![Figure 13. Angle Measurements are Initiated in Synchronized Angle Mode by a Falling Edge on the C̅N̅V̅  Signal](admt4000/figures/admt4000-f014.png)

*Figure 13. Angle Measurements are Initiated in Synchronized Angle Mode by a Falling Edge on the C̅N̅V̅  Signal*

### Changing Sequence Mode

When changing the sampling mode, the current conversion operation must be aborted. The current conversion sequence is aborted by setting Bits 15:14 of the Convert Start and Register Page Select register to 0b11 or with a rising edge on the C̅N̅V̅ (Pin 20), if configured as a C̅N̅V̅ input in the Digital Input/Output Enable Register. Once the conversion sequence mode has been updated, conversions are restarted by setting Bits 15:14 of the Convert Start and Register Page Select register to 0b00.

### Turn Count Behavior

There are three sensors in the ADMT4000, a GMR turn count sensor, a GMR quadrant detector, and an AMR angle sensor. The initial position is determined by the GMR turn count sensor with subsequent turn count positions derived from the AMR angle sensor combined with GMR quadrant detector. The GMR turn count sensor in the ADMT4000 provides true power-on turn count capability. When powered down, the ADMT4000 tracks the number of rotations of the external magnetic field between the 0 to 46 turn range shown by the red curve in Figure 14. On power-up, or at the start of a conversion sequence, the initial absolute position of the system is derived from the GMR turn count sensor combined with the AMR angle sensor (combined with the GMR quadrant detector) and is reported in the Absolute Angle Register. The GMR turn count sensor is used as the turn count reference for each measurement sequence in the one-shot mode but only for the initial sequence in the continuous conversion mode. The AMR angle sensor derived turn count has a range of -9 to 54 turns (blue curve in Figure 14). However, true power-on capability is only available in the 0 to 46 turn range of the GMR turn count sensor. If the external magnetic field is rotated beyond this range in the power-off state, the reported angle can be incorrect with no FAULT flag set after the next power-on. The extended range of the AMR angle sensor derived turn count is to facilitate system calibration only and should not be used in the normal operation of the part.

The GMR turn count sensor is decoded once during each measurement sequence and is used to verify the AMR angle sensor derived turn count. Figure 14 shows the behavior of the GMR turn count sensor derived turn count (red) and the AMR angle sensor derived turn count (blue):

- If the turn count has exceeded the maximum or minimum range, the reported position cycles within a range of one turn.
- The turn count cross check flag, Bit D13 in the FAULT register, is set high if the difference between the GMR turn count sensor derived position and the AMR angle sensor derived position exceeds 0.5 turns. For example, if the turn count is out of range of the GMR turn count sensor shown by the red curve in Figure 14. The FAULT flag, Bit D13, is not set if this happens while the part is powered down or if the part is in the one-shot mode.

![Figure 14. Turn Count Behavior vs. Input Magnetic Field Angle](admt4000/figures/admt4000-f016.png)

*Figure 14. Turn Count Behavior vs. Input Magnetic Field Angle*

Digitized data: [turn-count-behavior-vs-input-magnetic-field-angle.csv](admt4000/curves/turn-count-behavior-vs-input-magnetic-field-angle.csv) (x: Degrees; y: Degrees) — values read off the printed plot by the digitizer, not published data.

### Angle Measurement Filter

The ADMT4000 has an optional infinite impulse response (IIR) filter to reduce angle noise. The-IIR filter is enabled by setting the ANGLFILT Bit D12 of the General Register high:

- If the turn count is above 53.5 turns, the filter is bypassed. The filter is reenabled when the input drops below 53 turns again. Angle data is correct but is unfiltered in both cases.
- If the turn count is below -8.5 turns, the filter is bypassed and is only reenabled when the turn count is above -8 turns to prevent incorrect turn count data due to the wrapping at the end stop.

In the one-shot mode, the number of angle measurements reported depends on the turn count, since the angle measurement is only valid once the state of the GMR turn count sensor has been determined. Since the number of valid angle measurements available to be filtered varies depending on the absolute position of the system, it is recommended that the angle filter is not used in this conversion mode.

The transfer function for the IIR-filter is (see Figure 15):

*[Equation not captured in extraction — see Additional Figures, p. 17.]*

![Equation as printed (p. 17)](admt4000/figures/admt4000-eq01.png)

$$\text{Out}[n] = \text{Out}[n-1] + (\text{In}[n] - \text{Out}[n-1])/16$$

*LaTeX transcription of the equation above, checked against the symbols printed on the page.*

where:

In[n] is the current angle measurement. 




Out[n-1] is the previous filtered angle measurement.

Out[n] is the current filtered angle measurement.

Filtering occurs over the current angle measurement and the previous 15 angle measurements, this leads to a latency of 15 × 9 µs, assuming an angle measurement timing interval of 9 µs.

![Figure 15. IIR Transfer Function Used for the Angle Filter](admt4000/figures/admt4000-f017.png)

*Figure 15. IIR Transfer Function Used for the Angle Filter*

### GMR Turn Count Sensor Reset

Note that the user must reset the GMR turn count sensor once the GMR turn count sensor is assembled into the magnetic system of the final application.

The turn counter must also be reset if any of the following conditions are true:

- The GMR turn count sensor is exposed to a magnetic field greater than BMAX.
- Bit D9 or Bit D13 of the FAULT register are set.

Once the reset has been executed, the conversion sequence must be aborted and restarted before the ADMT4000 shows a turn count of 45 plus the actual reset angle used. The FAULT register, Table 14, has two bits that are used to indicate when a magnetic reset is required, Bit D9 and Bit D13. Bit D9 indicates that a false state of the GMR turn count sensor has been detected, and Bit D13 indicates that the turn count derived from the AMR angle sensor does not match the turn count derived from the GMR turn count sensor. The GMR turn count sensor can be reset by either rotating the external magnetic field 46 turns clockwise or by applying an external magnetic field at the required angle.

### Reset Using A Magnetic Field

The GMR turn count sensor can be reset by applying an external magnetic field with a field strength greater than 60 mT at the 315° orientation, as shown in Figure 16. This is irrespective of the current turn count value. Both sets of arrows in Figure 16 point from a magnetic north to a magnetic south. The solid arrows indicate the 0° direction and the dashed lines indicate the direction of the magnetic reset field, 315°. The user can generate the magnetic field in any way as long as the combined field strength of the application magnet (if installed) and the magnetic reset field is greater than 60 mT for a duration of no less than 10 µs. Typical methods of creating the magnetic reset field are:

- Using an electromagnet. This can be a wire coil close to the sensor embedded in the application circuit board or housing.
- Mechanically bring the application magnet closer to the sensor such that the field incident on the sensor is greater than 60 mT at 315°.

![Figure 16. Resetting the GMR Turn Count Sensor by Applying an External Magnetic Field](admt4000/figures/admt4000-f018.png)

*Figure 16. Resetting the GMR Turn Count Sensor by Applying an External Magnetic Field*

### Reset by Overturning the System Magnet

The GMR turn counter can be reset by turning the system magnet by 46 or more turns in the clockwise direction.

### Diagnostics and Fault Detection

The ADMT4000 has some built-in fault detection and diagnostic features to detect incorrect position information. The fault detection and diagnostic features result in a bit being set in the Fault Register. In addition, the SPI output frame includes the cyclic redundancy checks (CRCs) to validate a data transfer. For more details on the CRC coverage and implementation, see the relevant interface sections of this data sheet.

### FAULT Register Reported Errors

### ANGLE SENSOR RADIUS

The AMR angle sensor is configured as two AMR bridges offset by 45°, as shown in Figure 17, with the SINE and COSINE calculated, as shown in Table 8. The AMR angle sensor radius, SQRT(SINE^{2} + COSINE^{2}),  is compared against a factory preset limit. If it exceeds that limit, Bit D14 is set in the Fault Register.

![Figure 17. Sine and Cosine Signals from AMR Bridges of the Angle Sensor](admt4000/figures/admt4000-f019.png)

*Figure 17. Sine and Cosine Signals from AMR Bridges of the Angle Sensor*

**Table 8. SINE and COSINE Calculation from the AMR Bridge Measurements** ([table-07-p19-data.csv](admt4000/tables/table-07-p19-data.csv), p. 19)

| Function | Calculation |
|---|---|
| SINE | SIN_{p} − SIN_{n} |
| COSINE | COS_{p} − COS_{n} |

### TURN COUNT DIAGNOSTICS

To validate the GMR turn count sensor, the user must monitor the Fault Register. Some examples of errors that may transpire are as follows:

- Bit D9 of the Fault Register indicates an error relating to a false state of the GMR turn count sensor. An illegal state can happen if the following occurs:
- The sensor is exposed to a stray magnetic field larger than BMAX, which causes one or more elements of the sensor to change state out of sequence.
- A fault has developed in the sensor, which has caused an element not to change state when expected.
- The turn counter has been turned below typically 2 turns.
- Illegal value in the factory set the NVM for the GMR configuration.
- Bit D13 of the Fault Register indicates that the turn count derived from the GMR turn count sensor is different from the turn count derived from the AMR angle sensor. This can happen if the following occurs:
- The difference between the GMR based turn count sensor and the AMR based turn count exceeds 0.5 turns.
- The turn count is above 46.5 turns or below 0 turns.
- The redundant GMR turn count sensor decoder does not match the primary GMR turn count sensor decoder.
- An error occurs in the GMR turn count and AMR angle sensor combination logic.
- GMR quadrant sensor cross check error occurs.

### MEMORY

The ADMT4000 contains NVM, which is used to store factory set calibration, configuration, and device traceability data. Following a device reset, the contents of the NVM memory are loaded into the volatile memory. The NVM controller uses error correction codes (ECC), which can detect and correct single-bit errors and detect two-bit errors.

Following the NVM data being loaded into the volatile memory, if the ECC algorithm detects a 2-bit error, the device does not enter into normal operation. The detection of a fault is indicated to the user by BOOTLOAD output (Pin 4) remaining high and Bit D7 of the Fault Register set high. In this state, the SPI interface remains operational to interrogate the device registers. During operation, the contents of the data volatile memory loaded from NVM is continually checked using a CRC. If a fault is detected, then Bit D5 of the Fault Register is set. An ECC algorithm also protects the user-configuration registers. When the user updates the contents of these registers, the ECC Generation register must be updated in the ECCEDC register, Bit D7 of the Fault Register set high if a two-bit error is detected in the user-configuration register.

### POWER SUPPLIES

There are two power supplies for the ADMT4000 listed as follows:

- VDD provides the main power supply for the internal analog and digital functions.
- VDRIVE supplies the power supply for the GPIO and SPI ports.
- Undervoltage (UV) and overvoltage (OV) faults are detected and reported for VDD and VDRIVE. The user can check the status by monitoring Bit D0 to Bit D3 of the Fault Register, where a logic-high means that a fault state has been triggered.

### Serial-Peripheral Interface (SPI)

The ADMT4000 SPI is Mode 0 SPI compatible, that is, the clock polarity (CPOL) is 0, and the clock phase (CPHA) is 0. The interface consists of four signals: CS, SDI, SCLK, and SDO, as shown in Figure 29. The SDI line transfers data into the on-chip registers, and the SDO line transfers data from the on-chip registers. SCLK is the serial-clock input for the device and all data transfers take place with respect to SCLK. Data clocks into the ADMT4000 on the SCLK rising edge, and data clocks out of the ADMT4000 on the SCLK falling edge. The CS input frames the 32-bit serial data being transferred to or from the device to access the 16-bit device registers.

### ECC Generation

The ECCEDC register contains two ECC codes, ECC\_CONFIG0 and ECC\_CONFIG1. When calculating the ECC, it is important to order the configuration registers in the order shown in Table 30. For example, for ECC\_CONFIG0, the GENERAL register is at the lower end of the data set and the lower byte of the H3MAG register (H3MAG[7:0]) is at the upper end of the data set. Code to demonstrate how to implement the ECC calculation is available in the no-OS drivers for the ADMT4000.

### CRC Implementation

The CRC engine implements a 5-bit, x^{5} + x^{2} + 1, CRC polynomial using the serial linear feedback shift register (LFSR) approach and a seed value of 0x1F. The CRC is calculated on the following bits:

- SPI read: Rb/W bit and Address[5:0] on SDI, Data[15:0], the bit permanently set high, and conversion count[1:0] on SDO.
- SPI write: Rb/W bit, Address[5:0], Data[15:0] and the 3 following bits on SDI.

In both the SPI write and read modes, the CRC provides coverage on 26-bits, achieving a hamming distance of 3.

To calculate the CRC value from 26 bits of data, use the following pseudo code:

```
shft[5] = {1,1,1,1,1};  
for (i=30; i>=5; i--)  
{  
  xor_0 = data_in[i] ^ shft[4] ;  
  shft[4] = shft[3]; 
  shft[3] = shft[2];  
  shft[2] = shft[1] ^ xor_0;  
  shft[1] = shft[0];  
  shft[0] = xor_0;  
  }  
    Crc5calc = shft;
```

### Register Read Operations

### REGISTER READ

The register read operation is shown in Figure 18. Note the following:

- The first data bit sent by the microcontroller to the ADMT4000 is ignored.
- The second bit is set low to select the read register configuration.
- The 6-bit register address A5 to A0 is then clocked into the ADMT4000.
- On the next falling edge, the most significant bit (MSB) of the addressed register is clocked out of the ADMT4000, and the remaining 15 bits are clocked out on the following 15 falling edges of the clock.
- The first bit following the register data is always set high.
- A two-bit conversion counter (C1 and C0) increments, indicating that the measurement sequence has been completed. The conversion counter is increment after each successful conversion sequence and loops from 0b00 to 0b11.

- Following the life counter, a 5-bit CRC is included to enable the user to determine the integrity of the received data (for more details, see the CRC Implementation section).

When not transmitting data, the SDO line of the ADMT4000 is set to high impedance so that the part does not interfere with other devices on the SPI bus.

![Figure 18. SPI Register Read Operation](admt4000/figures/admt4000-f020.png)

*Figure 18. SPI Register Read Operation*

### ANGLE AND ABSANGLE READ

Reading the contents of the Angle Register and Absolute Angle Register is a special case. To ensure that the contents of the Angle Register and Absolute Angle Register are taken from the same sampling point, the user is required to read the contents of both the Angle Register and Absolute Angle Register as a single SPI transaction. The registers are updated when CS is high and keeping CS low prevents the second register from being updated before it can be read. The recommended method of reading the Angle Register and Absolute Angle Register registers is to use a single 64-bit write and read operation where the SPI frame is constructed from the 32bit read frames used for the Angle Register and Absolute Angle Register.

### Register Write Operations

The register write operation is shown in Figure 19. Note the following:

- The first data bit sent from the microcontroller to the ADMT4000 is ignored.
- The second bit is set high to select the write register configuration.
- The 6-bit register address A5 to A0 is then clocked into the ADMT4000.
- On the next rising edge, the first bit of the address register is clocked into the ADMT4000, and the remaining 15 bits are clocked in on the following 15 rising edges of the clock.
- The following 3 bits are not specified.
- The remaining 5 bits contain the frame CRC. For more details, see the CRC Implementation section.

![Figure 19. 32-Bit Write Operation for 16-Bit Register](admt4000/figures/admt4000-f021.png)

*Figure 19. 32-Bit Write Operation for 16-Bit Register*

### Device Identification

A set of unique identification registers are factory set for the ADMT4000:

- UNIQID0, UNIQID1, and UNIQID2 contain the codes that identify each individual part to allow full traceability.
- UNIQID3 contains the part type identification:

- Product type
- Voltage supply
- Silicon revision

The codes are accessed by a SPI register read.

### Calibration

### Basic Principle

Magnetic angle sensors are used for position sensing in many different applications. For applications where the end of a rotating shaft can be accessed, a low cost and highly accurate angle sensor can be implemented using just a simple dipole magnet and the ADMT4000, as shown in Figure 20.

![Figure 20. EV-ADMT4000SDV Evaluation Board in an End-of-Shaft Configuration](admt4000/figures/admt4000-f022.png)

*Figure 20. EV-ADMT4000SDV Evaluation Board in an End-of-Shaft Configuration*

### System Error Sources

For an end-of-shaft configuration, the highest system-level accuracy is achieved if the angle sensor is perfectly centered with the magnet.

Due to mechanical tolerances, nonidealities are seen on the angle measurements.

The four most significant types of mechanical and magnetic error sources are:

- Sensor alignment error. This is caused by a misalignment between the center of the magnetic field and the center of the angle sensor. See Figure 21.
- Magnet axis displacement error. This is caused by an incorrect centering of the magnet and the axis of the rotating shaft. See Figure 22.
- Magnet magnetization error. This is caused by tolerances in the magnet manufacturing process. See Figure 23.
- Magnet tilt error. This is caused by an inclination between the rotating shaft and the sensor, creating an irregular air gap. See Figure 24.

The above-mentioned mechanical and magnetic error sources manifest as harmonics in the data measured by the sensor. The error produced by misalignment can be analyzed by taking the Fourier transform of the measured data over multiple revolutions of the system.

![Figure 21. Sensor Alignment Error](admt4000/figures/admt4000-f023.png)

*Figure 21. Sensor Alignment Error*

![Figure 22. Magnet Axis Displacement Error](admt4000/figures/admt4000-f024.png)

*Figure 22. Magnet Axis Displacement Error*

![Figure 23. Magnetization Error](admt4000/figures/admt4000-f025.png)

*Figure 23. Magnetization Error*

![Figure 24. Magnet Tilt Error](admt4000/figures/admt4000-f026.png)

*Figure 24. Magnet Tilt Error*

### Calibration Procedure

The ADMT4000 contains a total of eight registers to enable the user to compensate for harmonic errors. 1^{st}, 2^{nd}, 3^{rd}, and 8^{th} harmonics can be corrected by writing to the appropriate harmonic magnitude (HxMAG) and phase (HxPH) registers. The calibration engine allows a wide range of mechanical errors to be corrected on chip, see the register descriptions for the various harmonic calibration coefficient ranges. The user must ensure that the harmonic calibration registers are set to zero before the calibration process is initiated.

The harmonic magnitude and phase values are typically extracted from the Fourier transform of a set of angle measurements taken with a magnetic field rotating with a constant angular velocity. Do the following steps to perform a calibration;

1. Perform a magnetic reset on the GMR turn count sensor.
2. Before the calibration process is initiated, the user must ensure that the harmonic calibration registers are set to zero. By default, the 1^{st}, 2^{nd}, 3^{rd} harmonics coefficients are set to zero, but the 8^{th} harmonic have a factory set value. If the user intends to update the 8^{th} harmonic coefficient, Bit 10 of the General Register must be set.
3. If the angle filter is enabled during calibration, the turn count range must be kept between 0 and 46 turns.
4. To avoid aliasing in the FFT algorithm:
   1. The number of measurements taken must be of the form 2^{N}, where N is an integer, typically 512 samples is sufficient.
   2. The number of rotations of the external magnetic field must be a prime number, 11 is typical.
5. It is recommended that calibration is performed with the CNVSYNC bit (13) set in the General Register.
6. The CNVSYNC function ensures that the SINE and COSINE measurements are synchronized with an external C̅N̅V̅ signal to reduce phase error. In the case where it is not possible to provide a C̅N̅V̅ signal, the part must be configured to operate with continuous conversions, this limits the effectiveness of the harmonic calibration but should still reduce errors due to imperfections in the magnetic system.
7. Once the AMR angle sensor has been calibrated, a magnetic reset of the GMR turn count sensor is highly recommended to ensure the part is in a known good state.


### Register Details

The register map for the ADMT4000 is split into pages. To access registers on a specific page, the appropriate page address must be written into the CNVPAGE register. The default (power-on-reset) value for each register is 0x0000, unless otherwise stated in Table 9. The CNVPAGE, ABSANGLE, DIGIO, ANGLE, and FAULT registers are page agnostic, which means that they can be accessed without setting the CNVPAGE register before they are addressed.

**Table 9. Register Map Summary** ([table-08-p25-register.csv](admt4000/tables/table-08-p25-register.csv), p. 25)

| Register | Function | Page | Address | Default Value | Access |
|---|---|---|---|---|---|
| CNVPAGE | Convert Start and Page Select | Agnostic | 0x01 | 0x0000 | R/W |
| ABSANGLE | Absolute Angle | Agnostic | 0x03 | 0xDB00 | R |
| DIGIO | Digital Input Output | Agnostic | 0x04 | 0x0000 | R/W |
| ANGLE | Angle Register | Agnostic | 0x05 | 0x8000 | R |
| FAULT | Fault Register | Agnostic | 0x06 | 0xFFFF | R/W |
| SINE | Sine Measurement | 0x00 | 0x10 | 0x0000 | R |
| COSINE | Cosine Measurement | 0x00 | 0x11 | 0x0000 | R |
| RADIUS | Angle Measurement Radius | 0x00 | 0x18 | 0x0000 | R |
| TMP | Temperature Sensor | 0x00 | 0x20 | 0x0000 | R |
| GENERAL | General Device Configuration | 0x02 | 0x10 | 0x1230 | R/W |
| DIGIOEN | Enable Digital Input/Outputs | 0x02 | 0x12 | 0x201F | R/W |
| CNVCNT | Conversion Count | 0x02 | 0x14 | 0x0000 | R |
| H1MAG | 1^{st} harmonic Error Magnitude | 0x02 | 0x15 | 0x0000 | R/W |
| H1PH | 1^{st} Harmonic Error Phase | 0x02 | 0x16 | 0x0000 | R/W |
| H2MAG | 2^{nd} Harmonic Error Magnitude | 0x02 | 0x17 | 0x0000 | R/W |
| H2PH | 2^{nd} Harmonic Error Phase | 0x02 | 0x18 | 0x0000 | R/W |
| H3MAG | 3^{rd} Harmonic Error Magnitude | 0x02 | 0x19 | 0x0000 | R/W |
| H3PH | 3^{rd} Harmonic Error Phase | 0x02 | 0x1A | 0x0000 | R/W |
| H8MAG | 8^{th} Harmonic Error Magnitude | 0x02 | 0x1B | 0x0000 | R/W |
| H8PH | 8^{th} Harmonic Error Phase | 0x02 | 0x1C | 0x0000 | R/W |
| ECCEDC | Error Correction and Detection Codes | 0x02 | 0x1D | 0xXXXX | R/W |
| UNIQID0 | Unique ID Register 0 | 0x02 | 0x1E | 0xXXXX | R |
| UNIQID1 | Unique ID Register 1 | 0x02 | 0x1F | 0xXXXX | R |
| UNIQID2 | Unique ID Register 2 | 0x02 | 0x20 | 0xXXXX | R |
| UNIQID3 | Product, Voltage Supply, and ASIC Revision | 0x02 | 0x21 | 0x0002 | R |
| ECCDIS | Error Correction Code Disable | 0x02 | 0x23 | 0x0000 | R/W |

### Page Agnostic Registers

### CONVERT START AND REGISTER PAGE SELECT

Address: 0x01, Reset: 0x0000, Name: CNVPAGE

The CNVPAGE register has two functions:

### Table 10. Bit Description for the CNVPAGE Register

**Table 10. Bit Description for the CNVPAGE Register** ([table-09-p26-register.csv](admt4000/tables/table-09-p26-register.csv), p. 26)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:14] | C̅N̅V̅ | 00 mimics the falling edge of convert start pin to trigger conversions. 11 mimics the rising edge of convert start pin to abort a conversion. | R/W |
| [13:5] | RESERVED | Reserved. | R |
| [4:0] | PAGE | Register Page Address. | R/W |

### ABSOLUTE ANGLE REGISTER

Address: 0x03, Reset: 0xDB00, Name: ABSANGLE

The ABSANGLE register stores the combined turn count and angle information with a range of 16560°.

ABSANGLE[15:8] contains the turn count in quarter turns.

ABSANGLE[15:10] contains the number of whole turns, including a code for an invalid turn count:

- 0b0000 00 to 0b1101 01: straight binary turn count.
- 0b1101 10: invalid turn count.
- 0b1101 11 to 0b1111 11: two's compliment turn count value.

The lower ten bits contain the angle information in straight binary with a resolution of 0.351°.

### Table 11. Bit Description for the ABSANGLE Register

**Table 11. Bit Description for the ABSANGLE Register** ([table-10-p26-register.csv](admt4000/tables/table-10-p26-register.csv), p. 26)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:0] | ABSANGLE | Absolute Angle. | R |

- **Note 1:** Select the page of the register that the user wants to access. If accessing multiple registers on the same page, set the CVNPAGE resister only before the first register access.
- **Note 2:** Trigger or abort a conversion sequence, setting bits 15:14 of the CNVPAGE register to 0b00 starts a conversion sequence, setting 0b11 aborts a conversion sequence, as shown in Table 10.

### DIGITAL INPUT OUTPUT REGISTER

Address: 0x04, Reset: 0x0000, Name: DIGIO

Depending on how the GPIO ports are configured with the DIGIOEN register, the DIGIO register is used to either set or read the state of GPIO ports. The GPIO pins are mapped directly to the bit position in the register, GPIO5 to GPIO0 are controlled by DIGIO[5:0], respectively.

### Table 12. Bits Description for the DIGIO Register

**Table 12. Bits Description for the DIGIO Register** ([table-11-p27-register.csv](admt4000/tables/table-11-p27-register.csv), p. 27)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:6] | RESERVED | Reserved. | R |
| [5:0] | DIGIO | GPIO Logic State. | R/W |

### ANGLE REGISTER

Address: 0x05, Reset: 0x8000, Name: ANGLE

The ANGLE register stores the angle information with the offset, gain, phase, and harmonic corrections applied and provides an accurate 0° to 360° position. For more details on when the angle register is updated, see the Sampling Modes section.

Angle Resolution = 360°/4096. 

*[Equation not captured in extraction — see the PDF.]*

**Table 13. Bit Description for the ANGLE Register** ([table-12-p27-register.csv](admt4000/tables/table-12-p27-register.csv), p. 27)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:4] | ANGLE | Magnetic Field Angle with 360° Range. | R |
| [3:0] | RESERVED | Reserved. | R |

### FAULT REGISTER

Address: 0x06, Reset: 0xFFFF, Name: FAULT

The FAULT register stores various fault flags. Following a power-on reset, the FAULT register is set to 0xFFFF. The user must verify that all bits can be set to 0xFFFF by reading this register at power up. After verifying the register functionality, the user must clear the register by writing 0x0000 to the register. A bit in the FAULT register stays set to high until the user writes 0x0000 to the FAULT register, the set fault bit does not clear if the potential fault condition persists.

**Table 14. Bit Description for the FAULT Register** ([table-13-p27-register.csv](admt4000/tables/table-13-p27-register.csv), p. 27)

| Bit | Function | Description | Status | Access |
|---|---|---|---|---|
| D15 | RESERVED | Reserved. | Not Active | R/W |
| D14 | AMR Angle Sensor Radius Check | AMR Angle Sensor Radius Check. | Active | R/W |
| D13 | Turn Counters Cross-Check Error | D13 bit flags if any of the following are detected: • The difference between turn count reported in the ABSANGLE register and the GMR turn count sensor exceeds 0.5 turns. • The turn count is above 46.5 turns or below 0 turns while the part is powered up. • The primary and redundant turn count decoders do not match. • There is a GMR turn count sensor and AMR angle sensor combination logic error. | Active | R/W |
|  |  | A GMR quadrant sensor decode error occurs. |  |  |
| D12 | RESERVED | Reserved. | Not Active | R/W |
| D11 | RESERVED | Reserved. | Not Active | R/W |
| D10 | RESERVED | Reserved. | Not Active | R/W |
| D9 | GMR Turn Count Sensor False State or Reference Resistor Flip | D9 flags if any of the following are detected: An unrecognized state of the GMR turn count sensor, A reference resistor in the wrong state, An illegal value (either 0x01 or 0b10) is set in the, CW/CCW NVM setting, The turn count is between 0 turns to typically 2 turns. | Active | R/W |
| D8 | RESERVED | Reserved. | Not Active | R/W |
| D7 | ECC Double Bit Error | Two-bit fault detected in NVM or user-configuration registers. | Active | R/W |
| D6 | RESERVED | Reserved. | Not Active | R/W |
| D5 | NVM CRC Fault | Nonvolatile memory CRC fault. | Active | R/W |
| D4 | RESERVED | Reserved. | Not Active | R/W |
| D3 | VDRIVE Overvoltage Detected | VDRIVE above the expected range, see Table 2. | Active | R/W |
| D2 | VDRIVE Undervoltage Detected | VDRIVE below the expected range, see Table 2. | Active | R/W |
| D1 | VDD Overvoltage Detected | VDD above the expected range, see Table 2. | Active | R/W |
| D0 | VDD Undervoltage Detected | VDD below the expected range, see Table 2. | Active | R/W |

### Page 0x0 Registers

### SINE REGISTER

Page: 0x00, Address: 0x10, Reset: 0x0000, Name: SINE

The SINE register contains the value of the sine portion of the AMR angle sensor without the sensor gain, offset, and harmonic calibration applied.

At the start of a measurement sequence, the register is set to 0x2000 and is updated once a valid measurement is available. The reset value of the register is 0x0000 and is stored in 2's complement data format.

**Table 15. Bit Description for the SINE Register** ([table-14-p29-register.csv](admt4000/tables/table-14-p29-register.csv), p. 29)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:2] | SINE | Uncorrected Sine Output. | R |
| [1] | RESERVED | Reserved. | R |
| [0] | STATUS | During continuous conversions, this flag is set high when new data is available. This flag is set low when the user reads the register contents. In One-Shot mode, this bit is always set low. | R |

### COSINE REGISTER

Page: 0x00, Address: 0x11, Reset: 0x0000, Name: COSINE

The COSINE register contains the value of the cosine portion of the AMR angle sensor without the sensor gain, offset, and harmonic calibration applied. At the start of a measurement sequence, the register is set to 0x2000 and is updated once a valid measurement is available. The reset value of the register is 0x0000 and is stored in 2's complement data format.

**Table 16. Bit Description for the COSINE Register** ([table-15-p29-register.csv](admt4000/tables/table-15-p29-register.csv), p. 29)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:2] | COSINE | Uncorrected Cosine Output. | R |
| [1] | RESERVED | Reserved. | R |
| [0] | STATUS | During continuous conversions, this flag is set high when new data is available. This flag is set low when the user reads the register contents. In One-Shot mode, this bit is always set low. | R |

### RADIUS

Page: 0x00, Address: 0x18, Reset: 0x0000, Name: RADIUS

The RADIUS register stores the magnitude of the vector from the SINE and COSINE angle measurements in bits 15 to 1, the RADIUS.

Resolution = 0.000924 mV/V. 

*[Equation not captured in extraction — see the PDF.]*

**Table 17. Bit Description for the RADIUS Register** ([table-16-p29-register.csv](admt4000/tables/table-16-p29-register.csv), p. 29)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:1] | RADIUS | Angle Vector Magnitude, or Radius. | R |
| [0] | STATUS | During continuous conversions, this flag is set high when new data is available. This flag is set low when the user reads the register contents. In One-Shot mode, this bit is always set low. | R |

### TEMPERATURE SENSOR 

Page: 0x00, Address: 0x20, Reset: 0x0000, Name: TMP

The Temperature Sensor register stores the temperature used for the AMR angle sensor and the GMR turn count sensor calibration. This register is set to 0xFFF0 at the start of every conversion sequence.

![Equation as printed (p. 30)](admt4000/figures/admt4000-eq02.png)
$$TMP_{DEGC} = ( TMP_{CODE} - 1168 ) / 15.66$$

where, TMP_{CODE} is the 12-bit register value and TMP_{DEGC} is the internal temperature in degrees Celsius.

*LaTeX transcription of the equation above, checked against the symbols printed on the page.*

### Table 18. Bit Description for the TMP Register

**Table 18. Bit Description for the TMP Register** ([table-17-p30-register.csv](admt4000/tables/table-17-p30-register.csv), p. 30)
| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:4] | TMP | Internal Temperature Sensor. | R |
| [3:0] | RESERVED | Reserved. | R |

### Page 0x2 Registers

### GENERAL REGISTER
Page: 0x02, Address: 0x10, Reset: 0x1230, Name: GENERAL
The GENERAL register enables control of the various functions of the ADMT4000. The GENERAL register is set to 0x1230 by default, which configures the device as follows:
- Convert start synchronization mode off.- Angle filter enabled.- Factory set 8^{th} harmonic calibration coefficients.- Continuous conversion mode.- STORAGE[7:0] set to 0x00.

**Table 19. Bit Description for the GENERAL Register** ([table-18-p30-register.csv](admt4000/tables/table-18-p30-register.csv), p. 30)

| Bit | Bit Name | Description | Access | 
|---|---|---|---| 
| [15] | STORAGE[7] | Available for user data storage and part of ECC calculation. | R/W | 
| [14:13] | CNVSYNC | Convert Start Synchronization Mode. 00: Sequencer controls the start of the sampling of the SINE and COSINE channels. 01: Not valid. 10: Not valid. 11: Synchronize sampling instants of SINE and COSINE channels to convert start edge. | R/W | 
| [12] | ANGLFILT | Filter on Calculated Angle. 0: Filter disabled. 1: Filter enabled. | R/W | 
| [11] | STORAGE[6] | Available for user data storage and part of ECC calculation. | R/W | 
| [10] | H8CNTRL | 8^{th} Harmonic Correction Source. 0: ADI factory-set values. | R/W |
|  |  | 1: User-supplied values. |  |
| [9] | RESERVED | This bit must be set 1. | R/W | 
| [8:6] | STORAGE[5:3] | Available for user data storage and part of ECC calculation. | R/W | 
| [5:4] | RESERVED | This bit must be set to 0b11. | R/W | 
| [3:1] | STORAGE[2:0] | Available for user data storage and part of ECC calculation. | R/W | 
| [0] | CNVMDE | Conversion Mode. 0: Continuous conversions. 1: One-shot conversion, sequencer stops at the end of the conversion sequence. | R/W |

### DIGITAL INPUT/OUTPUT ENABLE REGISTER


Page: 0x02, Address: 0x12, Reset: 0x201F, Name: DIGIOEN

All digital Input/Outputs can be used either in functional mode or GPIO mode. The relevant digital Input/Output pin can be configured as GPIO by setting the corresponding bit in the lower byte of this register high.

To enable the output drivers of the digital Input/Output pins, the bit for the corresponding pin must be set high. When the driver enable bit is set low and the function is set to GPIO the pin is configured as an input.

By default, DIGIOEN is configured to enable the BOOTLOAD output at power on.

**Table 20. Bit Description for the DIGIOEN Register** ([table-19-p31-register.csv](admt4000/tables/table-19-p31-register.csv), p. 31)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:14] | RESERVED | Reserved. | R |
| [13] | DIGIO5EN | 1: GPIO5 output enable. 0: GPIO5 output disable. | R/W |
| [12] | DIGIO4EN | 1: GPIO4 output enable. 0: GPIO4 output disable. | R/W |
| [11] | DIGIO3EN | 1: GPIO3 output enable. 0: GPIO3 output disable. | R/W |
| [10] | DIGIO2EN | 1: GPIO2 output enable. 0: GPIO2 output disable. | R/W |
| [9] | DIGIO1EN | 1: GPIO1 output enable. 0: GPIO1 output disable. | R/W |
| [8] | DIGIO0EN | 1: GPIO0 output enable. 0: GPIO0 output disable. | R/W |
| [7:6] | RESERVED | Reserved. | R |
| [5] | DIGIO5FNC | 1: GPIO5. 0: BOOTLOAD (output only). | R/W |
| [4] | DIGIO4FNC | 1: GPIO4. 0: Reserved. | R/W |
| [3] | DIGIO3FNC | 1: GPIO3. | R/W |
|  |  | 0: ACALC (output only). |  |
| [2] | DIGIO2FNC | 1: GPIO2. 0: Reserved. | R/W |
| [1] | DIGIO1FNC | 1: GPIO1. 0: C̅N̅V̅ (input only). | R/W |
| [0] | DIGIO0FNC | 1: GPIO0. 0: BUSY (output only). | R/W |

### CONVERSION COUNT REGISTER

Page: 0x02, Address: 0x14, Reset: 0x0000, Name: CNVCNT

The CNVCT register stores the conversion count information and is updated every time a conversion sequence is completed. The conversion counter does not increment if the conversion sequence is aborted early by initiating a new conversion sequence whilst the current conversion sequence is executing. On reaching the full scale value of 0xFF, the counter wraps around to 0x00.

**Table 21. Bit Description for the CNVCNT Register** ([table-20-p32-register.csv](admt4000/tables/table-20-p32-register.csv), p. 32)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:8] | RESERVED | Reserved. | R |
| [7:0] | CNVCNT | Conversion Count. | R |

### 1ST HARMONIC ERROR CALIBRATION MAGNITUDE

Page: 0x02, Address: 0x15, Reset: 0x0000, Name: H1MAG

The H1MAG register stores the amplitude of the 1^{st} harmonic error. The user must multiply the calculated harmonic coefficient by the CORDIC scaler of 0.6072 and write the resulting unsigned integer to the register. The LSB is 11.2455°/2^{11} = 0.005493°.

**Table 22. Bit Description for the H1MAG Register** ([table-21-p32-register.csv](admt4000/tables/table-21-p32-register.csv), p. 32)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:11] | RESERVED | Reserved. | R |
| [10:0] | H1MAG | 1^{st} Harmonic Error Amplitude. | R/W |

### 1ST HARMONIC ERROR CALIBRATION PHASE

Page: 0x02, Address: 0x16, Reset: 0x0000, Name: H1PH

The H1PH register stores the phase of the 1^{st} harmonic error as an unsigned integer with an LSB of 360°/2^{12} = 0.087891°.

**Table 23. Bit Description for the H1PH Register** ([table-22-p32-register.csv](admt4000/tables/table-22-p32-register.csv), p. 32)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:12] | RESERVED | Reserved. | R |
| [11:0] | H1PH | 1^{st} Harmonic Error Phase. | R/W |

### 2ND HARMONIC ERROR CALIBRATION MAGNITUDE

Page: 0x02, Address: 0x17, Reset: 0x0000, Name: H2MAG

The H2MAG register stores the amplitude of the 2^{nd} harmonic error. The user must multiply the calculated harmonic coefficient by the CORDIC scaler of 0.6072 and write the resulting unsigned integer to the register. The LSB is 11.2455°/2^{11} = 0.005493°.

### Table 24. Bit Description for the H2MAG Register

**Table 24. Bit Description for the H2MAG Register** ([table-23-p33-register.csv](admt4000/tables/table-23-p33-register.csv), p. 33)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:11] | RESERVED | Reserved. | R |
| [10:0] | H2MAG | 2^{nd} Harmonic Error Amplitude. | R/W |

### 2ND HARMONIC ERROR CALIBRATION PHASE

Page: 0x02, Address: 0x18, Reset: 0x0000, Name: H2PH

The H2PH register stores the phase of the 2^{nd} harmonic error as an unsigned integer with an LSB of 360°/2^{12} = 0.087891°.

### Table 25. Bit Description for the H2PH Register

**Table 25. Bit Description for the H2PH Register** ([table-24-p33-register.csv](admt4000/tables/table-24-p33-register.csv), p. 33)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:12] | RESERVED | Reserved. | R |
| [11:0] | H2PH | 2^{nd} Harmonic Error Phase. | R/W |

### 3RD HARMONIC ERROR CALIBRATION MAGNITUDE

Page: 0x02, Address: 0x19, Reset: 0x0000, Name: H3MAG

The H3MAG register stores the amplitude of the 3^{rd} harmonic error. The user must multiply the calculated harmonic coefficient by the CORDIC scaler of 0.6072 and write the resulting unsigned integer to the register. The LSB is 1.40076°/2^{8} = 0.005493°.

### Table 26. Bit Description for the H3MAG Register

**Table 26. Bit Description for the H3MAG Register** ([table-25-p33-register.csv](admt4000/tables/table-25-p33-register.csv), p. 33)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:8] | RESERVED | Reserved. | R |
| [7:0] | H3MAG | 3^{rd} Harmonic Error Amplitude. | R/W |

### 3RD HARMONIC ERROR CALIBRATION PHASE

Page: 0x02, Address: 0x1A, Reset: 0x0000, Name: H3PH

The H3PH register stores the phase of the 3^{rd} harmonic error as an unsigned integer with an LSB of 360°/2^{12} = 0.087891°.

### Table 27. Bit Description for the H3PH Register

**Table 27. Bit Description for the H3PH Register** ([table-26-p34-register.csv](admt4000/tables/table-26-p34-register.csv), p. 34)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:12] | RESERVED | Reserved. | R |
| [11:0] | H3PH | 3^{rd} Harmonic Error Phase. | R/W |

### 8TH HARMONIC ERROR CALIBRATION MAGNITUDE

Page: 0x02, Address: 0x1B, Reset: 0x0000, Name: H8MAG

The H8MAG register stores the amplitude of the 8^{th} harmonic error. The user must multiply the calculated harmonic coefficient by the CORDIC scaler of 0.6072 and write the resulting unsigned integer to the register. The LSB is 1.40076°/2^{8} = 0.005493°.

### Table 28. Bit Description for the H8MAG Register

**Table 28. Bit Description for the H8MAG Register** ([table-27-p34-register.csv](admt4000/tables/table-27-p34-register.csv), p. 34)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:8] | RESERVED | Reserved. | R |
| [7:0] | H8MAG | 8^{th} Harmonic Error Amplitude. | R/W |

### 8TH HARMONIC ERROR CALIBRATION PHASE

Page: 0x02, Address: 0x1C, Reset: 0x0000, Name: H8PH

The H8PH register stores the phase of the 8^{th} harmonic error as an unsigned integer with an LSB of 360°/2^{12} = 0.087891°.

**Table 29. Bit Description for the H8PH Register** ([table-28-p34-register.csv](admt4000/tables/table-28-p34-register.csv), p. 34)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:12] | RESERVED | Reserved. | R |
| [11:0] | H8PH | 8^{th} Harmonic Error Phase. | R/W |

### ECCEDC

Page: 0x02, Address: 0x1D, Reset: 0x0000, Name: ECCEDC

The ECCEDC register stores the error correction and detection codes (ECC) required when the user-configuration registers are updated. The ECC provides single bit error correction and double bit error detection capability. The hex value of 0x000F should be included in the ECC calculation, as shown in Table 30.

**Table 30. Bit Description for the ECCEDC Register** ([table-29-p35-register.csv](admt4000/tables/table-29-p35-register.csv), p. 35)

| Bits | Bit Name | Description | Access |
|---|---|---|---|
| [15:8] | ECC_CONFIG1 | ECC for: H3MAG[15:8] H3PH H8MAG H8PH | R/W |
| [7:0] | ECC_CONFIG0 | ECC for: GENERAL DIGIOEN 0x000F H1MAG H1PH H2MAG H2PH H3MAG[7:0] | R/W |

### UNIQUE ID REGISTER 0

Page: 0x02, Address: 0x1E, Reset: 0xXXXX, Name: UNIQID0

Unique identification register 0.

### Table 31. Bit Description for the UNIQID0 Register

**Table 31. Bit Description for the UNIQID0 Register** ([table-30-p35-register.csv](admt4000/tables/table-30-p35-register.csv), p. 35)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:0] | UNIQID0 | Unique Device Identification 0. | R |

### UNIQUE ID REGISTER 1

Page: 0x02, Address: 0x1F, Reset: 0xXXXX, Name: UNIQID1

Unique identification register 1.

**Table 32. Bit Description for the UNIQID1 Register** ([table-31-p35-register.csv](admt4000/tables/table-31-p35-register.csv), p. 35)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:0] | UNIQID1 | Unique Device Identification 1. | R |

### UNIQUE ID REGISTER 2

Page: 0x02, Address: 0x20, Reset: 0xXXXX, Name: UNIQID2

Unique identification register 2.

### Table 33. Bit Description for the UNIQID2 Register

**Table 33. Bit Description for the UNIQID2 Register** ([table-32-p36-register.csv](admt4000/tables/table-32-p36-register.csv), p. 36)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:0] | UNIQID2 | Unique Device Identification 2. | R |

### UNIQUE ID REGISTER 3

Page: 0x02, Address: 0x21, Reset: 0x0002 Name: UNIQID3

Unique identification register 3.

### Table 34. Bit Description for the UNIQID3 Register

**Table 34. Bit Description for the UNIQID3 Register** ([table-33-p36-register.csv](admt4000/tables/table-33-p36-register.csv), p. 36)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:11] | RSDV | Reserved. | R |
| [10:8] | ID_PROD | Product Identifier. | R |
| [7:6] | ID_SUPY | Voltage Supply Identifier. | R |
| [5:3] | RSDV | Reserved. | R |
| [2:0] | ID_REVN | ASIC Silicon Revision. | R |

### ECC DISABLE

Page: 0x02, Address: 0x23, Reset: 0xXXXX, Name: ECCDIS

The ECCDIS register is used to disable single bit error correction of the user-configuration registers. The user must disable ECC before updating the configuration registers (see the ECCEDC register description) by setting the contents of the ECCDIS register to 0x4D54. Once the configuration registers have been updated, and the new ECC code added to the ECCEDC register, ECC must be reenabled by writing a value other than 0x4D54 to the ECCDIS register, it is recommended that a value of 0x0000 is used.

**Table 35. Bit Description for the ECCDIS Register** ([table-34-p36-register.csv](admt4000/tables/table-34-p36-register.csv), p. 36)

| Bit | Bit Name | Description | Access |
|---|---|---|---|
| [15:0] | ECCDIS | Set to 0x4D54 to disable ECC on the configuration registers. Set to 0x0000 to enable ECC on the configuration registers. | R/W |

### APPLICATIONS

### Rotational Speed Considerations

With the filter enabled, there is a latency between the current angle of the system and the angle reported. The worst-case error due to the latency is dependent on the maximum speed of the system. The worst-case error in degrees is 864 × 10^{−6} × rotation speed (rpm), in addition to latency due to the SPI interface.

### Magnet Considerations

The maximum and minimum field strength that can be used with the ADMT4000 is bounded, defined by the red and blue curves (B_{MAX} and B_{MIN}) in Figure 25 for NdFeB and Figure 26 for SmCo. As shown in the plot, this usable field strength range is temperature dependent. The operating magnetic field range is measured in the x, y plane of the sensor at the center of the GMR (turn count) sensor, as shown in Figure 30. The z component of the external magnetic field does not influence the behavior of the GMR turn count or AMR angle sensor.

To extend the operating temperature range of the system, the user must consider the selection of the system magnet. The temperature coefficient of the magnetic field strength of a magnet is a characteristic of the magnetic material. Typical examples of a NdFeB and a SmCo magnet are shown in Figure 25 and Figure 26 alongside the typical maximum operating range of the ADMT4000. The green shaded areas in Figure 25 and Figure 26 show the expected performance of a typical NdFeB and SmCo magnet, including temperature variation and manufacturing tolerances. The design of the green shaded region must ensure that the magnetic flux density never goes beyond the B_{MAX} and B_{MIN} limits, under worst-case conditions of mechanical tolerances, stray magnetic field influence, temperature, and lifetime.

![Figure 25. Typical NdFeB Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor](admt4000/figures/admt4000-f027.png)

*Figure 25. Typical NdFeB Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor*

Digitized data: [typical-ndfeb-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-co.csv](admt4000/curves/typical-ndfeb-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-co.csv) (x: °C; y: mT) — values read off the printed plot by the digitizer, not published data.

![Figure 26. Typical SmCo Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor](admt4000/figures/admt4000-f028.png)

*Figure 26. Typical SmCo Magnet Performance vs. Magnetic Operating Window of the GMR Turn Count Sensor*

Digitized data: [typical-smco-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-cou.csv](admt4000/curves/typical-smco-magnet-performance-vs-magnetic-operating-window-of-the-gmr-turn-cou.csv) (x: °C; y: mT) — values read off the printed plot by the digitizer, not published data.

The turn count error rate is determined by the constant magnetic flux density that the GMR turn count sensor is exposed to. Figure 27 shows the error rate for 1 million parts vs. the magnetic flux density for the various number of expected cycles in the target application. For example, a constant magnetic flux density of 16 mT is required to ensure less than 1 failure per 1 million parts after 10 million cycles per part.

![Figure 27. Minimum Magnetic Feld Strength on the GMR Turn Count Sensor vs. Error Rate](admt4000/figures/admt4000-f029.png)

*Figure 27. Minimum Magnetic Feld Strength on the GMR Turn Count Sensor vs. Error Rate*

Digitized data: [minimum-magnetic-feld-strength-on-the-gmr-turn-count-sensor-vs-error-rate.csv](admt4000/curves/minimum-magnetic-feld-strength-on-the-gmr-turn-count-sensor-vs-error-rate.csv) (x: mT; y: ppm) — values read off the printed plot by the digitizer, not published data.

### Typical System Configuration

Figure 28 and Figure 29 show how the ADMT4000 can be configured to operate in the case where GPIO functions are used and when they are not required,

In the case where the GPIO functions are not required, Figure 28, the GPIO ports must be configured as digital inputs and connected to GND through a 100 kΩ resistor. Pin 4, Bootload, must be connected to VDRIVE by 100 kΩ resistor, since at power up, the BOOTLOAD function is set by default. Figure 29 shows the case where the GPIO

functions are required, in this case, the GPIOs are set to outputs except for Pin 20, C̅N̅V̅ , which has been configured as the convert start input.

![Figure 28. Typical System Configuration for the Case where no GPIO Functions are Required](admt4000/figures/admt4000-f030.png)

*Figure 28. Typical System Configuration for the Case where no GPIO Functions are Required*

![Figure 29. Typical System Configuration for the Case where GPIO Functions are Required](admt4000/figures/admt4000-f031.png)

*Figure 29. Typical System Configuration for the Case where GPIO Functions are Required*

### OUTLINE DIMENSIONS

![other (p. 40)](admt4000/figures/admt4000-f032.png)

![Figure 30. 24-Lead Thin Shrink Small-Outline Package (TSSOP)](admt4000/figures/admt4000-f033.png)

*Figure 30. 24-Lead Thin Shrink Small-Outline Package [TSSOP]*

![other (p. 40)](admt4000/figures/admt4000-f034.png)

![other (p. 40)](admt4000/figures/admt4000-f035.png)

Figure 30. 24-Lead Thin Shrink Small-Outline Package [TSSOP] 
(RU-24) Dimensions Shown in millimeters 
 
### ORDERING GUIDE

### Table 36. Ordering Guide

**Table 36. Ordering Guide** ([table-35-p40-data.csv](admt4000/tables/table-35-p40-data.csv), p. 40)

| Model | Temperature Range | Package Description | Package Option |
|---|---|---|---|
| ADMT4000BRUZAB | −40°C to +125°C Ambient | 24-Lead TSSOP, 3.3 V | RU-24 |

ADMT4000

**NOTES**

ALL INFORMATION CONTAINED HERE IN IS PROVIDED 'AS IS' WITHOUT REPRESENTATION OR WARRANTY. NO RESPONSIBILITY IS ASSUMED BY ANALOG DEVICES FOR ITS USE, NOR FOR ANY INFRINGEMENTS OF PATENTS OR OTHER RIGHTS OF THIRD PARTIES THAT MAY RESULT FROM ITS USE. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. NO LICENCE, EITHER EXPRESSED OR IMPLIED, IS GRANTED UNDER ANY ADI PATENT RIGHT, COPYRIGHT, MASK WORK RIGHT, OR ANY OTHER ADI INTELLECTUAL PROPERTY RIGHT RELATING TO ANY COMBINATION, MACHINE, OR PROCESS WHICH ADI PRODUCTS OR SERVICES ARE USED. TRADEMARKS AND REGISTERED TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS.

## Additional Figures