最新情報 (1)

製品概要

機能と利点

  • 5 kV rms signal and power isolated CAN transceiver
  • isoPower integrated isolated dc-to-dc converter
  • VIO pin for 1.7 V to 5.5 V logic levels
  • ISO 11898-2: 2016 compliant (CAN FD)
  • Data rates up to 12 Mbps for CAN FD
  • Low maximum loop propagation delay: 150 ns
  • Extended common-mode range: ±25 V
  • Bus fault protection: ±40 V on CANH and CANL pins
  • Low power standby support remote wake request
  • Extra isolated signal for control (such as termination switches)
  • Passes EN 55022 Class B by 6 dB
  • Slope control for reduced EMI
  • Safety and regulatory approvals
    • VDE certificate of conformity, VDE V 0884-10 (pending):
      • VIORM = 565 VPEAK
    • UL: 5000 V rms for 1 minute per UL 1577 (pending)
    • CSA Component Acceptance 5A at 5 kV rms (pending)
      • IEC 60950-1, IEC 61010-1
  • Creepage and clearance: 8.3 mm with 20-lead SOIC_IC
  • High common-mode transient immunity: >75 kV/μs
  • Industrial temperature range: −40°C to +105°C

製品概要

The ADM3055E is a 5 kV rms isolated controller area network (CAN) physical layer transceiver with an integrated isolated dc-to-dc converter. The ADM3055E meets CAN flexible data (FD) rate requirements for operation to 5 Mbps and higher, and complies with the ISO 11898-2 standard.

The device employs Analog Devices, Inc., iCoupler® technology to combine a 3-channel isolator, a CAN transceiver, and Analog Devices isoPower® dc-to-dc converter into a single, small outline integrated circuit (SOIC), surface-mount package. The device is powered by a single 5 V supply realizing a fully isolated solution for CAN and CAN FD applications. Radiated emissions from the high frequency switching of the dc-to-dc convertor are kept below EN 55022 Class B limits by continuous adjustments to the switching frequency.

The ADM3055E provides complete isolation between the CAN controller and physical layer bus. Safety and regulatory approvals (pending) for 5 kV withstand voltage, 565 VPEAK working voltage, 10 kV surge test, and 8.3 mm creepage and clearance ensure that the ADM3055E meets application isolation requirements.

Low propagation delays through the isolation support longer bus cables. Slope control mode is available for standard CAN at low data rates. Standby mode minimizes power consumption when the bus is idle or if the node goes offline. Silent mode allows the TXD input to be ignored for listen only.

Dominant timeout functionality protects against bus lock up in a fault condition. The current limiting and thermal shutdown features protect against output short circuits. The device is fully specified over an industrial temperature range of −40°C to +105°C.

Applications

  • CANOpen, DeviceNet, and other CAN bus applications
  • Industrial automation
  • Process control and building control
  • Transport and infrastructure

製品ライフサイクル icon-recommended 新規設計にお薦めします

発売済みの製品です。データシートには、最終的な仕様と動作条件がすべて記載されています。新規の設計には、これらの製品の使用を推奨します。

評価キット (1)

設計リソース

ADI has always placed the highest emphasis on delivering products that meet the maximum levels of quality and reliability. We achieve this by incorporating quality and reliability checks in every scope of product and process design, and in the manufacturing process as well.  "Zero defects" for shipped products is always our goal.

ディスカッション

ADM3055E 探していたものは見つかりませんでしたか? » 是非アナログ・コミュニティ(英語)を覗いてみて下さい»

サンプル&購入

PC版サイトでは、サンプルと製品の購入をいただけます。


価格は1個当たりの米ドルで、米国内における販売価格(FOB)で表示されておりますので、予算のためにのみご使用いただけます。 また、その価格は変更 されることがあります。米国以外のお客様への価格は、輸送費、各国の税金、手数料、為替レートにより決定されます。価格・納期等の詳細情報については、弊社正規販売代理店または担当営業にお問い合わせください。なお、 評価用ボードおよび評価用キットの表示価格は1個構成としての価格です。

 

モデル一覧の項目説明