Functional Description
The 3B42, 3B43 and 3B44 are single-channel AC sine wave signal conditioning modules which use an AC averaging technique to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals ranging from 20 mV to 550 V rms to give an rms output reading. Simultaneous precision voltage and current outputs are provided. including isolation (±1500 V peak input-to-output and power). The 3B42 and 3B43 modules withstand 220 V rms, and Model 3B44 withstands 550 V rms at its input terminals without damage, thereby shielding computer-side circuitry from field-side overvoltage conditions. Each plug-in, mix-and-match, hot-swappable module is easily field calibrated via front-panel zero and span adjustments for both voltage and current outputs.
3B Series Custom-Ranging Program
Externally-programmable versions, Models 3B42-00, 3B43-00 and 3B44-00, enable the user to configure a special input range by using the optional plug-on AC1310 ranging card, which houses user-supplied resistors to determine zero and span. To facilitate selecting resistors, a Windows® program, 3B-CUSTOM, calculates resistor values based on the user-desired input/output ranges.
Inside the 3B42, 3B43 and 3B44 Modules
Signal isolation by transformer coupling uses a proprietary modulation technique for linear, stable and reliable performance. The differential input circuit on the field side is fully floating, eliminating the need for any input grounding. A demodulator on the computer side of the signal transformer recovers the original signal, which is then filtered and buffered to provide a low-noise, low-impedance output signal.
Figure 1. 3B42, 3B43, 3B44 Functional Block Diagram
Figure 2. 3B42, 3B43, 3B44 Input Field Connections |
3B42: 3B43: 3B44: Dual Outputs 0 to +10 V 4 mA to20 mA or 0 to 20 mA |
3B42, 3B43 and 3B44 Models Available
| Model | Input Range | Output Ranges1 | |
|---|---|---|---|
| Order Now | 3B42-00 | Externally Programmable2 | 0 V to +10 V & 0 mA to 20 mA |
| Order Now | 3B42-01 | 0 mV to +50 mV rms | 0 V to +10 V & 0 mA to 20 mA |
| Order Now | 3B42-02 | 0 mV to +100 mV rms | 0 V to +10 V & 0 mA to 20 mA |
| 3B42-Custom | * | * | |
| Model | Input Range | Output Ranges1 | |
| Order Now | 3B43-00 | Externally Programmable2 | 0 V to +10 V & 0 mA to 20 mA |
| Order Now | 3B43-01 | 0 V to +10 V rms | 0 V to +10 V & 0 mA to 20 mA |
| 3B43-Custom | * | * | |
| Model | Input Range | Output Ranges1 | |
| Order Now | 3B44-00 | Externally Programmable2 | 0 V to +10 V & 0 mA to 20 mA |
| Order Now | 3B44-01 | 0 V to +150 V rms | 0 V to +10 V & 0 mA to 20 mA |
| Order Now | 3B44-02 | 0 V to +250 V rms | 0 V to +10 V & 0 mA to 20 mA |
| 3B44-Custom | * | * |
1 Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
2 Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
3B42, 3B43 and 3B44 Specifications
(typical @ +25�C and ±15 V dc, and +24 V dc Power)
| Description | Model 3B42 | Model 3B43 | Model 3B44 |
|---|---|---|---|
| Input Ranges | |||
| Standard Ranges, 50 Hz to 400 Hz | Refer to Model Table | Refer to Model Table | Refer to Model Table |
| Custom Ranges, 50 Hz to 400 Hz | 20 mV rms to 1 V rms | 1 V rms to 50 V rms | 50 V rms to 550 V rms |
| Output Ranges | |||
| Voltage (RL > 2 kΩ) | 0 V to +10 V | * | * |
| Current (RL + 0 to 850 Ω)1 | 4 mA to 20 mA or 0 mA to 20 mA | * | * |
| Accuracy2 | |||
| Initial @ +25�C | ±0.05% Span | * | * |
| Nonlinearity | ±0.02% Span | * | * |
| Stability vs. Temperature | |||
| Voltage Output | |||
| Zero | ±0.005% of Span/�C | * | * |
| Span | ±0.005% of Reading/�C | * | * |
| Current Output3 | |||
| Zero | ±25 ppm of Span/�C | * | * |
| Span | ±25 ppm of Reading/�C | * | * |
| Zero and Span Adjustment Range4 | ±5% of Span | * | * |
| Input Bias Current | +1 nA | +5 nA | +3 nA |
| Input Resistance | 100 MΩ | 250 kΩ | 1 MΩ |
| Noise | |||
| Input, 0.1 Hz to 10 Hz Bandwidth | 5 µV rms | * | * |
| Output, Ripple and Noise | 50 µV rms | * | * |
| Bandwidth, -3 dB | 3 Hz | * | * |
| Output Rise Time, 10% to 90% Span | 200 ms | * | * |
| Common-Mode Voltage (CMV) | |||
| Input-to-Output, Continuous | ±1500 V peak, maximum | * | * |
| Transient | ANSI/IEEE C37.90.1-1989 | * | * |
| Common Mode Rejection (CMR) | |||
| 1 kΩ Source Imbalance, 50/60 Hz | 100 dB | * | * |
| Input Protection | |||
| Continuous | 220 V rms, maximum | * | 550 V rms, continous |
| Transient | ANSI/IEEE C37.90.1-1989 | * | * |
| Voltage Output Protection | Continuous Short to Ground | * | * |
| Current Output Protection | 130 V rms, continuous | * | * |
| Power Supply Voltages 5 | |||
| ±15 V dc Supplies | |||
| Rated Operation | ±(11.5 V dc to 16.5 V dc) | * | * |
| Current | ±10 mA | * | * |
| Sensitivity | ±0.01% span/V | * | * |
| +24 V dc Loop Supply | |||
| Rated Operation | +12 V dc to +30 V dc | * | * |
| Current | +27 mA @ lout = 20 mA | * | * |
| Sensitivity | ±0.0002% span/V | * | * |
| Mechanical Dimensions | 3.15" x 3.395" x 0.775" (80.0 mm x 86.2 mm x 19.7 mm) |
* | * |
| Environmental | |||
| Temperature Range | |||
| Rated Performance | -25�C to +85�C | * | * |
| Storage | -55�C to +85�C | * | * |
| Relative Humidity, 24 hours | 0 to 95% @ +60�C noncondensing | * | * |
| RFI Susceptibility | ±0.5% Span error @ 400 MHz, 5 Watt, 3 ft | * | * |
* Specifications same as model 3B42.
1 For a 0 to 20 mA range, a typical minimum output current is 10 µA.
2 Includes the combined effects of repeatability, hysteresis, and nonlinearity.
3 With respect to the voltage output.
4 A wide range of custom zero suppression and span is available with Models 3B42-00, 3B43-00 and 3B44-00, using the AC1310 ranging card.
5 +24 V dc loop power is required for driving the current output at loads up to 850Ω. If a current output load of 400Ω or less is applied, +15 V dc is sufficient for loop power. If only voltage output is used, loop power is not required.
Specifications subject to change without notice.
© 1995 - Analog Devices, Inc. All Rights Reserved